Member Name
Data Type
Bit Number
Data Length
Byte Offset
32 bit
Output Control Echo
DINT
4 Byte
8
Out1 Echo
0
1 bit
Out2 Echo
1
1 bit
Out3 Echo
2
1 bit
Reserved
3 - 31
29 bit
32 bit
External Input Status
DINT
4 Byte
12
Trigger
0
1 bit
New Master
1
1 bit
Reserved
2 - 31
30 bit
32 bit
External Output Status
DINT
4 Byte
16
Out1
0
1 bit
Out2
1
1 bit
Out3
2
1 bit
Reserved
3 - 31
29 bit
32 bit
Device Status
DINT
4 Byte
20
Reserved
0
1 bit
New Master Requedted
1
1 bit
Reserved
2 - 7
6 bit
Scanning Disabled
8
1 bit
Reserved
9 - 15
7 bit
In Read Cycle
16
1 bit
Actively Scanning
17
1 bit
Reserved
18 - 31
14 bit
32 bit
Read Cycle Sequence
C
ount
er
UDINT
0 - 31
4 byte
24
32 bit
Trigger Count
UDINT
0 - 31
4 byte
28
32 bit
Decode/
Matchcode
Count
UDINT
0 - 31
4 byte
32
32 bit
Mismatch Count
UDINT
0 - 31
4 byte
36
32 bit
No Read
Count
UDINT
0 - 31
4 byte
40
32 bit
Decode Data Length
UDINT
0 - 31
4 byte
44
Decode Data
String
SINT[128]
0 - 1024
128 byte
48
MXL/SLC Input Assembly (Instance ID: 102)
Compared to the Large Input Assembly, the MXL/SLC Input Assembly holds the more detailed Device
Status information and Read result character strings of up to 184 bytes. When reading multiple sym-
bols, the Read strings are output delimited by Separator Characters.
MXL/SLC Input Assembly Member Structure
Member Name
Size (Bytes)
INFO BITS
1
RESERVED
1
CONFIGURATION CHANGE DETECTION
1
RESERVED
1
DEVICE STATUS
4
FAULT CODE
4
COUNTERS
24
READ CYCLE REPORT
8
Appendices
A - 8
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings