Member Name
Data Type
Bit Number
Data Length
Byte Offset
32 bit
Decode Location Top
0 - 15
2 byte
Decode Location Left
0 - 15
2 byte
32 bit
Decode Location Height
0 - 15
2 byte
Decode Location Width
0 - 15
2 byte
32 bit
Code Type
DINT
4 Byte
52
Aztec Code
1 bit
Micro QR Code
1 bit
Postal Code
1 bit
Code 39
1 bit
Codabar
1 bit
Interleaved 2 of 5
1 bit
UPC EAN
1 bit
Code 128 EAN 128
1 bit
Code 93
1 bit
PDF417
1 bit
Pharma Code
1 bit
DataMatrix
1 bit
QR Code
1 bit
BC412
1 bit
RSS14
1 bit
RSS14 LTD
1 bit
RSS14 EXP
1 bit
Micro PDF
1 bit
Composite
1 bit
Dot Code
1 bit
Reserved
12 bit
32 bit
Pixels per Element
REAL
0 - 31
4 byte
56
32 bit
Decode
Data
Length
DINT
0 - 31
4 byte
60
Decode Data
String
SINT[436]
0 - 3487
436 byte
64
4 Decode Input Assembly (Instance ID: 104)
4 Decode Input Assembly is designed to hold the Read result information of 4 symbols. The first Read
result is stored in a 160 byte field. The remaining Read results are stored in a 72 byte field. Use this
when you want to execute a multiple symbol Read for up to 4 symbols and query symbol information
such as symbol position coordinates for each symbol.
4 Decode Input Assembly Member Structure
Member Name
Size (Bytes)
INFO BITS
1
RESERVED
1
CONFIGURATION CHANGE DETECTION
1
RESERVED
1
DEVICE STATUS
4
FAULT CODE
4
COUNTERS
24
READ CYCLE REPORT
8
Appendices
A - 18
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
- 31