4 Controlling Operation and Data Output with PROFINET
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
4-3 Settin
g Up
PROFINET
Com
m
u
n
ication
s
4
4-3-1 Configuring
Network
Settings in the
V430-F
7
The
Advanced Settings
will appear. Check the settings indicated by the red boxes.
EtherNet/IP
connection is
Enabled
by default. Disable EtherNet/IP and set
PROFINET
to
Enabled
.
If the IP address needs to be changed (when connecting multiple V430s, for example), configure the
IP Address
as needed for your application.
To use PROFINET communication, the settings below must be configured.
for the definition of input and output modules.
Communications Settings Procedure
Memory Assignments
Configure Network Settings of
V430-F
Configure Default PROFINET Settings
Configure IO Supervisor (Computer)
Settings
• IP Address Settings
Configure IO Controller Settings
• IP Address Settings
• PROFINET IO System Settings
• IO Device Settings and Assignments
• Compile and Save Settings
Transfer Settings and Check Connection
• Check IO Controller Connection
• Transfer Parameters
• Check Connection Status
• Check Data Assignments
Set in WebLink
Configure the settings with the engineering tool. If you are setting the
V430-F
as an IO device, install a GSD file that defines the V430
-F
IO
data CR connection information in the engineering tool. The V430
-F
GSD file can be downloaded from our website. For PROFINET IO
system settings, refer to applicable engineering tool manual(s).
Connect the computer (engineering tool), V430
-F
, and external
devices, and use the engineering tool to transfer settings and
check
communication.