Bit
Signal Name
0
OUTPUT 1
1
OUTPUT 2
2
OUTPUT 3
3 - 31
Reserved
Numeric value in Bit
0 = OFF
1 = ON
•
Device Status
Displays code reader status
Bit
State
Description
0
Reserved
‐
1
New Master Requested
When the bit is ON, the next read result is registered
as the Master Symbol.
2 - 7
Reserved
‐
8
Scanning Disabled
When the bit is ON, the Read Cycle is Disabled.
9 - 15
Reserved
‐
16
In Read Cycle
Bit is ON when In Read Cycle.
17
Actively Scanning
When the bit is ON, the Read Cycle is Disabled.
•
R
ead Cycle Sequence Counter
Stores the current Read Cycle Count.
•
Trigger Counter
Stores the current total number of triggers input.
•
Decode/
Matchcode
Counter
Stores one of the following.
(1)
Total number of Good Reads (When
Matchcode
: Disabled)
(2)
Total number of matches to the Master Symbol (When
Matchcode
: Enabled)
•
Mismatch Counter
Stores the total number of Mismatches (not matching Master Symbol).
•
No Read
Counter
Stores the total number of No Reads.
•
Decode Data Length
Stores the number of characters in the Read string.
•
Decode Data
String
Stores the Read string. When additional information such as Print Quality Grading Standard is set, it
is stored following the Read string.
Appendices
A - 6
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings