Tag Set Settings
Setting Item
Setting
Input
Tag Set Name
Tag Set Name on PLC
Size
Input Assembly Dependency
•
84, 176, 248, 500 byte
Output
Tag Set Name
Tag Set Name on PLC
Size
Output Assembly Dependency
•
4 and 12 byte
Connection Settings
Setting Item
Setting
Input
Target Variable
Input Assembly Dependency
•
100, 101, 102, 103, 104, 105
Size
Input Assembly Dependency
•
84, 176, 248, 500 byte
Originator Variable
Variable defined on the PLC
Size
Input Assembly Dependency
•
4 and 12 byte
Connection type
Point to Point connection
RPI
1.0 to 65.0ms (Default: 5.0ms)
Timeout
RPI × (4 to 512) (Default: RPI × 512)
Output
Target Variable
Output Assembly Dependency
•
197, 198
Size
Output Assembly Dependency
•
4 and 12 byte
Originator Variable
Variable defined on the PLC
Size
Output Assembly Dependency
•
4 and 12 byte
Connection type
Point to Point connection
3 Controlling Operation and Data Output with Ethernet
3 - 9
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
3-1 Controlling Operation and Data Output with Ether-
Net/IP
3
3-1-5
T
ag Data Link Setting Methods