3-1-6
Status and Control Signals for Each Input and Output Assembly
The V430
-F
has the following types of Input Assemblies.
(1) Small Input Assembly
(2) Large Input Assembly
(3) MXL/SLC Input Assembly
(4) 1 Decode Input Assembly
(5) 4 Decode Input Assembly
(6) N Decode Input Assembly
The Status signals are as follows.
These signals are controlled automatically based on the status of the code reader.
○: Verifiable
×: Not Verifiable
Status Sig-
nal
Description
(1)
(2)
(3)
(4)
(5)
(6)
InReadCy-
cle
While in Read Cycle, this bit is set to
1
.
×
○
×
×
×
×
Trigger Ac-
knowledged
This bit becomes
1
when the Trigger bit from the Out-
put Assembly is received.
When the Trigger bit is OFF, Trigger Acknowledged al-
so becomes
0
.
×
×
○
○
○
○
Exposure
Done
During exposure, this bit is set to
1
.
When Exposure is done, this bit becomes
0
.
×
×
○
○
○
○
Decoding
When reader is decoding image
, this bit is set to
1
.
When
the decode is completed,
this bit becomes
0
.
×
×
○
○
○
○
Data is
Ready
When the data from Read Cycle Report and Data Cy-
cle Report is confirmed, this bit becomes
1
.
When the next Read starts, this bit becomes
0
.
×
×
○
○
○
○
Read Cycle
Pass
On Good Read
(or Match if Matchcode enabled)
,
bit
becomes
1
.
When next Read starts,
bit becomes
0
.
×
×
○
○
○
○
Read Cycle
Fail
On
No
Read
(or Mismatch if Matchcode enabled)
, bit
becomes
1
.
When next Read starts,
bit becomes
0
.
×
×
○
○
○
○
Decode
Data
This field stores the Read string. When additional in-
formation such as Print Quality Grading Standard is
set, it is stored following the Read string.
○
○
○
○
○
○
The following are the two
V430-F
Output Assembly types.
(1) Output Assembly
(2) Output Assembly (Legacy)
The Control Signals are as follows.
They can be controlled by the user at an arbitrary timing.
○: Verifiable
×: Not Verifiable
Control Signal
Description
(1)
(2)
Trigger
Executes Read. The code reader recognizes this bit changing from 0 to
1 as the rising edge of the trigger and its change from 1 to 0 as the fall-
ing edge of the trigger.
○
○
3 Controlling Operation and Data Output with Ethernet
3 - 11
V430-F Series Autofocus Multicode Reader User Manual for Communication Settings
3-1 Controlling Operation and Data Output with Ether-
Net/IP
3
3-1-6
Status and Control Signals for Each Input and Output Assembly