Страница 2: ...allation Checkpoints Tips 1 Check Point before Installation 1 1 Selection of Cable 1 2 Recommended Cable Type and Permissible Length Cable 2 Check Point during Installation 2 1 Termination Resistors 2 2 How to Connect Termination Resistors Termination Resistors for 2 Wire RS485 Communication System Termination Resistors for 4 Wire RS422 Communication System 2 3 Grounding System for Communication C...

Страница 3: ...2 Connection Multiple RFK505s Connections 3 TCP IP Communication Port Connection Optional 4 TCP IP Converter External Version 10 Initial Setup 1 System Initialization 2 Entering Setup Mode 3 Time Date Setting 11 Operation 1 Normal Operation 2 Default Setting 12 Setting Changes 1 SETUP MENU F1 1 1 Time Setting 1 2 Communication Address 1 3 BAUD RATE 1 4 Reader 1 Internal Reader Mode 1 5 Reader 2 Ex...

Страница 4: ...ing 3 Setup Menu F3 4 NOT USE 4 1 Firmware Version 4 2 Memory Test 4 3 Output Test 4 4 LCD Test 4 5 키 패드 테스트 4 6 Reader Test 4 7 Input DIP Switch Test 4 8 Communication Test 13 Appendix 1 Default Values for Parameters 14 FCC REGISTRATION INFORMATION 15 RMA Request 37 37 38 38 39 39 39 40 40 41 41 42 42 43 43 44 45 45 46 47 ...

Страница 5: ...he user to the presence of importa nt operating and maintenance servicing instructions in the literature accompanying the ap pliance WARNING To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture WARNING 1 Be sure to use only the standard adapter that is specified in the specification sheet Usin g any other adapter could cause fire electrical shock or damage ...

Страница 6: ...t in any way SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair 10 When cleaning do not spray water directly onto parts of the product Doing so may ca use fire or electric shock CAUTION 1 Do not drop objects on the product or apply strong blows to it Keep away from a locat ion subject to excessive vibration or magnetic interference 2 Do not install in a loc...

Страница 7: ...u r safety If the provided plug does not fit into your outlet consult an electrician for repla cement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenie nce receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table spe...

Страница 8: ...splay The Star RFK505 displays current time on the LCD and has back lighting on the keypad that ensures you successful operation The Star RFK505 allows you to access door with proximity card and personal PIN numbers Three LEDs in the front panel of green yellow and red ins ide Piezo Buzzer sound and LCD will guarantee you accurate and reliable system operation ...

Страница 9: ...ads with Back Lighting Current Time Display on the LCD Dual Tamper Switches Reverse Polarity Protection Compatible Controller 26bit Wiegand iMDC iCON100 iTDC Third Party Controller Standalone Controller 34bit Wiegand iMDC iCON100SR iTDCSR Third Party Controller Standalone Controll er RFK505 Built in 125KHz 4 Proximity Reader IPK505 ASK EM Format Built in 125KHz 4 Proximity Reader SRK505 Built in 1...

Страница 10: ...le Required Baud Rate 9 600bps default 4 800bps 19 200bps 38 400bps 57 600bps 115200bps Selectable Output Fo rmat RFK505 IPK505 26bit Wiegand 4 8bit Burst for PIN SRK505 34bit Wiegand 4 8bit Burst for PIN LCD Character LCD 2Linges x 16Char 2 62 x 0 55 65 6mm x 13 8mm Screen Keypad 16 Key Numeric Keypad with Back Lighting LED Indicator 7 Array LED Indicators Red Green and Yellow on the front a nd b...

Страница 11: ...p 7 Color Material Dark Pearl Gray Polycarbonate Dimension W x H x T 161 5mm x 134mm x 48 5mm 6 36 x 5 28 x 1 9 Weight 547g 1 21lbs ...

Страница 12: ...plied Parts 5 p 8 Please unpack and check the contents of the box If any of these parts are missing please co ntact your distributor or service center Optional accessories if purchased may be included in the Gift Box ...

Страница 13: ...ng status card n umber and current time on the LCD Setting Changes The Star RFK505 manages output mode setting external buzzer control and external LED control Keypad If the Star RFK505 is not connected to a host PC the integrated keypad and LCD displ ay module can be used for the entire programming process 2 Product Explanation ...

Страница 14: ...ED is turned on During the reader transmits card data to the controller the green LED is turned on When temper switch is operated yellow LED is turned on 3 10 Numeric Key pad You can operate the unit manually by using the key pad 4 Function Key pad The unit has four Function keys F1 F2 F3 F4 5 Card Reading Status LED When a card is read the card reading status LED turns on green ...

Страница 15: ... System Initialization for more d etails 2 Communication Display LED 3 4 yellow green LED will twinkle during RS232 RS422 and TCP IP communicatio n If the LAN is connected normally during TCP IP communication green LED will turn o n But in the collision status the 2 LED red turns on 3 Tamper Switch If someone takes off installed Star RFK505 on the wall by force the tamper switch is a ctivated then...

Страница 16: ...egand Data1 IN DATA0 Cyan OUTPUT CON5 TTL Output1 DATA0 Output Orange with White Stripe TTL Output2 DATA1 Output Brown with White Stripe OK Signal Out Not use Green with Red Stripe Error Signal Out Not use Blue with Red Stripe Tamper Switch Out Tamper Switch Out Yellow with White Stripe RS232 INTERFACE CON2 RS232 TX TXD Black with White Stripe RS232 RX RXD Read with White Stripe Ground GND Black R...

Страница 17: ...p 13 Wire Color Table RS422 TX TX Yellow RS422 TX TX Gray RS422 RX RX Blue RS422 RX RX Brown TCP IP Communication CON6 TCP IP Communication 8PIN Connecter Module IO PORT NAME SIGNAL NAME COLOR CODED ...

Страница 18: ... be installed with common hand tools and readily available communications wires This section provides i nformation about wiring wire runs and other information to make the installation quick an d easy 1 Check Point before Installation 1 1 Selection of Cable System installation cabling will be configured as follow ...

Страница 19: ...onductor shielded 300m Belden 9514 22 AWG 8 conductor shielded Door Lock Alarm Device Lock Alarm Controller Belden 9409 18AWG 2 conductor unshielded 300m RS232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair shielded 15m RS485 Cable Controller Converter Controller Controller Controller RFK505 RFK505 RFK505 RFK505 Converter Belden 9829 24 AWG 2 twisted pair shielded 1 200m RS422 Cable Co...

Страница 20: ...ted signal will stabilize 18 6us after the leading edge of a bit Since the data bit is cap tured in the middle of the bit which is approximately 52us after the leading edge of a bit Th e reflection stabilizing time 18 6us is much before the center of the bit therefore the termin ation resistors are not required However if you install the cable to maximum length the impedance of cable and network i...

Страница 21: ...e will be a current flow through the shield wire whe n the voltage level of both ends of shield wire is not equal and this current flow will create n oise and interfere to communications For the good grounding we recommend to connecting ONLY one end of shield wire of com munication cable to grounding system If you find earth ground nearby then connect one e nd of shield wire to earth ground If you...

Страница 22: ...Installation Checkpoints Tips p 18 ...

Страница 23: ...mplate on the back of this manual to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown bel ow Skip this step if the gang box is already installed on the wall 2 Using 2 screws install wall mount to the wall ...

Страница 24: ... cable of the main unit th rough the center hole and push the main unit to wall mount to lock the main unit and t hen make sure that the main unit is locked with wall mount 2 System Initialization You have to initialize the Star RFK505 prior to installation After power is supplied to the Star RFK505 press the Initialization Switch on the back of the RFK505 unit and then keep it for more than 2 sec...

Страница 25: ...ower to the GND Black wire 3 2 Wiegand Data Connection Connect DATA0 IN wire of the controller to WEIGAND DATA 0 wire of RFK505 Orange with White stripe Connect DATA1 IN wire of the controller to WEIGAND DATA 1 wire of RFK505 Brown with White stripe If the controller and RFK505 use separate power sources you must connect the G ND between the controller and RFK505 4 Wire Connection to Access Contro...

Страница 26: ...eader use separate power sources you must con nect the GND between the controller and the external reader Compatible Readers External Reader RFK505 IPK505 Standard 26BIT Wiegand Format Proximity Readers Standard 26BIT Wiegand 8BIT Burst Format Proximity and Keypad Reader RF TINY RF10 RF20 RF30 RF70 RF500 RFK101 FGR006 FGR006EX iP10 iP20 IP30 iPK101 SRK505 Standard 34BIT Wiegand Format Proximity Re...

Страница 27: ...2 GND of RFK505 to the pin 5 of the 9 pin connector Plug in the 9 pin connector to COM1 or COM2 port of the host PC Install and run application software 2 RS422 Communication Port Connection 2 1 RS422 Connection Single RFK505 Connection RS422 RS232 converter INC400 is required to use RS422 communication between the RFK 505 and a host computer Please follow the instruction below Connect RS422 TX of...

Страница 28: ...422 communication between multiple RFK505s and a host computer Please follow instruction below 1 First you have to connect all RS422 port of all RFK505s in parallel I Connect RS422 TX of one RFK505 to RS422 TX of another RFK505 II Connect RS422 TX of one RFK505 to RS422 TX of another RFK505 III Connect RS422 RX of one RFK505 to RS422 RX of another RFK505 IV Connect RS422 RX of one RFK505 to RS422 ...

Страница 29: ...all and run application software 3 TCP IP Communication Port Connection Optional Optional TCP IP module is required to use TCP IP communication between multiple RFK505 and the PC Please follow the instruction below 1 Connect the LAN cable of the network system to the RJ45 jack of the RFK505 2 If you install multiple RFK505 units and only one TCP IP port is available you may conne ct one RFK505 to ...

Страница 30: ...e of a RFK505 without a module RFK505 with TCP IP Module RFK505 without TCP IP Module Yellow Blue Gray Brown Blue Yellow Brown Gray 3 Set a unique Communication Address for each RFK505 4 Install and run the applications software 4 TCP IP Converter External Version When you use the TCP IP converter choose either RS232 converter or RS422 converter ...

Страница 31: ...K505 ILAN422 LINE COLOR RS232 TX CON2 RX RS232 DSUB9 BLACK WHITE RX CON2 TX RS232 DSUB9 RED WHITE GND CON2 GND BLACK RS422 TX CON3 RX RS422 CONNECTOR GRAY TX CON3 RX RS422 CONNECTOR YELLOW RX CON3 TX RS422 CONNECTOR BROWN RX CON3 TX RS422 CONNECTOR BLUE ...

Страница 32: ...e RFK505 Then the LCD will first display Initiali ze OK 1 Yes 0 No Press 1 key if you want to initialize the system or 0 to cancel the i nitialization procedure After all the initialization process is completed the system will be op erating in the normal mode and the LCD will display RFK505 F1 MM DD hh mm ss If initialization is completed all of the data in the device will be deleted ...

Страница 33: ...n the main Setup Menu and you can scroll up or down the menu by pressing the 4 or 6 key If you press the ESC key then the RFK505 will exit the Setup Mode and return to normal ope ration in Reader Mode The default Master ID for the SR505 is 0000000000 Press the 0 key 10 times 3 Time Date Setting After you enter the Setup Mode you will see the following screen with the current date and time To adjus...

Страница 34: ...per Switch After RFK505 is installed on the wall if someone take the RFK505 off from the wall th en YELLOW LED is on and buzzer is activated continuously 2 Default Setting When you operate the RFK505 first time or you initialize the RFK505 the controller will setu p all values to defaults Factory Settings You can change the settings for desired applicatio n Please refer to the APPENDIX section at ...

Страница 35: ...Setting Changes 12 p 31 To setup or to change the RFK505 IPK505 settings the user has to enter the SETUP MENU first To do so input Master ID Default setting 00000000 and the user can get into SETUP ...

Страница 36: ...P MENU F3 and F4 key for SETUP MENU F4 Th ere are several SUB MENUs in the main SETUP MENU and the user can scroll up and down t he SUB MENU by pressing 4 and 6 key in the main SETUP MENU If the user pressed E SC key RFK505 IPK505 will be out of the SETUP MENU and returned to normal operation The Master ID for SRK505 is 10 times 0 key Default setting The RFK505 IPK505 SRK505 don t use SETUP MENU F...

Страница 37: ...s is a unique number assigned to each device for communication T he default address is 033 For proper communication with the PC it is important that the value you set here should ma tch the value you set on the application software It is also important to make sure each devi ce on a loop has a unique address To change the communication address of the RFK505 press ENT enter the desired 3 Digi t add...

Страница 38: ...t be set the same as th e TCP IP module setting If communication has problem 1 Check the status of COMM Address Registration It has to be same as Applicatio n Software 2 Check the matching Communication Speed Baud rate It has to be same as Ap plication Software 3 Check the matching port between PC communication port and Application Soft ware port 4 Check the setting for communication environment o...

Страница 39: ...ault is 00000000 Beware that if you forget the Master ID you cannot access the Setup Mode To change the Master ID press ENT and then either enter the desired 8Digit Master ID or present a card to the reader For the SRK505 the Master ID is 10Digits long in the range of 0000000000 to 429 4967295 When the Master ID card registration is successfully completed the LCD displays the REGIS TRATION OK mess...

Страница 40: ...in the device such as card data input output setting Time Schedules etc Before you initialize the system make sure you do not need the data stored in the device To initialize the RFK505 press ENT and then press 1 to confirm If you wish to cancel a nd exit without initialization press 0 instead Device address and communication speed is maintained 2 SETUP MENU F2 ...

Страница 41: ...To change the setting press ENT and press 4 or 6 to select STATUS or CARD NO a nd then press ENT to confirm 2 2 Buzzer Status The buzzer generates a beep when a button on the keypad is pressed when a card is read when an error occurs etc To enable or disable the buzzer sound press ENT and press 4 or 6 to select ENABLE or DISABLE and press ENT to confirm The buzzer beeps regardless of this setting ...

Страница 42: ...4 LED Buzzer Control This function controls the LED and Buzzer of the reader GL Green LED controls the card reading status YL Yellow LED controls the error indication in case a user card isn t authorized BZ Buzzer It controls the buzzer sound e g GL03 YL03 BZ01 When card is presented to the unit green LED indicator is l it for 3sec If a user card isn t authorized the yellow LED indicator is lit an...

Страница 43: ...t PIN Input is enabled If you choose Disable you cannot gain access via password input when using RF PW mode 2 6 Key Output Type Setting You can change the Output Mode with pressing function keys 4BIT BURST 4bit burst will be output when you press function keys 8BIT BURST 8bit burst will be output when you press function keys 3 Setup Menu F3 사용되지 않습니다 ...

Страница 44: ...Setting Changes p 40 4 NOT USE 4 1 Firmware Version ...

Страница 45: ...5 To begin the test press ENT If the test is successful the LCD will display the TEST PASSED message Press any key to fini sh the test If the test is unsuccessful the LCD will display the TEST FAILED message Press any key to finish the test and try again If the problem persists please contact your loca l IDTECK dealer for assistance or service 4 3 Output Test ...

Страница 46: ...l the tests are over press any key to exit 4 4 LCD Test LCD Test allows you to test the LCD of the RFK505 To begin the test press ENT Once the test begins the LCD will display a series of different screens Ensure that all the screens on the LCD are properly displayed The test ends with the display of the firmware update date YYYY MM DD After the test is finished press any key to exit 4 5 키 패드 테스트 ...

Страница 47: ...efers to the built in reader of the RFK505 and Reader 2 refers to an e xternal reader You can also use Reader Test to check the number of a card Master number of SR 505 is in the range of 10digits 4 7 Input DIP Switch Test Input Test allows you to check the status of Input Ports and DIP switches Communication A ddress Setting Switches To begin the test press ESC DIP Switch 1 ON 2 OFF It shows how ...

Страница 48: ...nication Prior to the test connect the RS232 RX wire Black wire with White stripe and the RS232 TX wire Red wire with Black stripe together To begin the test press ENT If the test is successful the LCD will display the TEST PASSE D message Press any key to finish the test If the test is unsuccessful the LCD will display th e TEST FAILED message Press any key to finish the test and try again after ...

Страница 49: ...Appendix 13 p 45 1 Default Values for Parameters No Parameters INITIAL SETTING VALUE 1 READER 1 Operation Mode ID ONLY 2 READER 2 Operation Mode ID ONLY 3 READER 1 Keypad Input Limit USE ...

Страница 50: ...e received including interference that may caus e undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital De vice pursuant to Part 15 of the FCC rules These limits are designed to this equipment gener ates uses and can radiate radio frequency energy and if not installed and used in accordan ce with the instructions may cause harmful interference...

Страница 51: ...g Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Website www idteck com E Training Center http www idtecktraining com IDTECK Production Facility and RMA Center 2F 89 4Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 420 130 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Website www idteck com E Training Center http www idtecktr...