107
Transfers the 8 positioning actions for the X axis. Because address 101 is
empty and has no data, the group of 8 addresses is considered non-sequen-
tial.
WRIT(87)
#0040
DM k
n
j+6
(02)
j+6
(01)
25506
l (15)
j + 6 (02)
j + 6 (00)
j + 6 (01)
( = )
Transfer of 8 addresses
for X-axis positioning actions
j+6(00): set as differentiated input
l(15): Command Ready
Transfers the 9 positioning actions of the Y axis. Without any empty ad-
dresses, the group of 9 positioning actions is considered sequential.
WRIT(87)
#0038
DM k + 50
n
j+7
(02)
j+7
(01)
25506
l (15)
j + 7 (02)
j + 7 (00)
j + 7 (01)
( = )
Transfer of 9 addresses
for Y-axis positioning actions
j+7(00): Differentiated input
l(15): Command Ready
Transfer Program (1)
Transfer Program (2)
Data Transmission Program
Section 8-2