88
CompoWay/F Message Communications
Section 4-5
Write Basic Settings
The data contents are shown in the following table.
Write Timer Setting
Writes the timer setting for the OFF-delay, ON-delay, or one-shot timer as a 4-
digit hexadecimal value. The setting range is “0000” to “00C8” (0 to 200 ms),
but the possible settings are restricted as follows:
An error will occur if a write operation is executed using a setting interval that
does not meet the restrictions.
Write Hysteresis Width
Writes the hysteresis width as a 4-digit hexadecimal value.
Bit
Contents
00
Display Contents:
0: Digital incident level
1: Digital percentage
2: Analog incident level
01
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
2: Peak
3: Bottom
04
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
2: Long-distance
3: High-speed
07
08
Timer Mode:
1: OFF-delay
2: ON-delay
3: One-shot
09
10
Number of Display Digits:
0: 4 digits
1: 3 digits
2: 2 digits
3: 1 digit
4: 0 digits
11
12
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Timer setting
Setting interval
0 to 20 ms
1-ms increments
20 to 200 ms
5-ms increments
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...