83
CompoWay/F Message Communications
Section 4-5
Read Basic Settings
Reads the basic settings as shown in the following table.
Read Timer Setting
Reads the timer setting of the OFF-delay, ON-delay, or one-shot timer as a 4-
digit hexadecimal value. The value is set in ms.
Read Hysteresis Width
Reads the hysteresis width as a 3-digit hexadecimal value. Bits 14 and 15 are
used to display the sensing setting
Bit
Contents
00
Display Contents:
0: Digital incident level
1: Digital percentage
2: Analog incident level
01
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
2: Peak
3: Bottom
04
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
2: Long-distance
3: High-speed
07
08
Timer Mode:
1: OFF-delay
2: ON-delay
3: One-shot
09
10
Number of Display Digits:
0: 4 digits
1: 3 digits
2: 2 digits
3: 1 digit
4: 0 digits
11
12
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Bit
Contents
00 to 11
Hysteresis Width
12
Always 0.
13
Always 0.
14
Sensing Setting:
0: Standard
2: Long-distance
3: High-speed
15
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...