33
Explicit Message Communications
Section 2-6
This command cannot be used if one or more E39-TM1 Terminal Block Units
is connected.
Read Basic Settings
Reads the basic settings of the Sensor for the unit number specified in the
instance ID. The data contents are as follows:
Read Timer Settings
Reads the OFF-delay, ON-delay, and one-shot timers of the Sensor for the
unit number specified in the instance ID. The data is given as a 2-byte (4-digit)
hexadecimal value. The value is given in ms.
Bit
Contents
00
Display Contents:
0: Digital incident level
1: Digital percentage
2: Analog incident level
01
02
Display Orientation:
0: Standard
1: Reversed
03
Hold Setting:
0: OFF
2: Peak
3: Bottom
04
05
Flashing Setting:
0: OFF
1: ON
06
Sensing Setting:
0: Standard
2: Super long-distance
3: Super high-speed
07
08
Timer Mode:
1: OFF-delay
2: ON-delay
3: One-shot
09
10
Number of Display Digits:
0: 4 digits
1: 3 digits
2: 2 digits
3: 1 digit
4: 0 digits
11
12
13
Always 0.
14
Teaching during RUN
0: OFF
1: ON
15
Eco Mode
0: OFF
1: ON
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...