85
CompoWay/F Message Communications
Section 4-5
Read Special Flags
Reads the status of the following setting items. This command is possible with
E3X-DA6TW and E3X-DA8TW Sensors only. An error will occur if this com-
mand is executed for any other Sensor.
Note Bits 00, 01, and 07 are read as 0 or 1 according to the internal status of the
Sensor.
Response Codes
Normal Completion
Error Completion
Bit
Contents
00
0 or 1
01
0 or 1
02
Always 0.
03
Always 0.
04
Operating Mode Flag (one-word):
0: Dark-ON
1: Light-ON
05
Operating Mode Flag (two-word):
0: Dark-ON
1: Light-ON
06
Area Setting Flag:
0: AREA OFF
1: AREA ON
07
0 or 1
08
Always 0.
09
Always 0.
10
Always 0.
11
Always 0.
12
Always 0.
13
Always 0.
14
Always 0.
15
Always 0.
Response code
Name
Description
“0000”
Normal completion
No error has occurred.
Response
code
Error name
Cause
“1001”
Command too long
The command is too long.
“1002”
Command too short
The command is too short.
“1003”
Number of elements/
data mismatch
The number of data does not match the number
of elements.
“1101”
Area type error
The area type is wrong.
“1103”
Start address out-of-
range error
The read start address is out of range.
The unit number of an unconnected Sensor is
specified as the read start address.
The bit position is set to other than “00”.
“1104”
End address out-of-
range error
The specified number of elements is out of
range.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...