79
CompoWay/F Message Communications
Section 4-5
Response Block
The following diagram shows the command text in the CompoWay/F response
block.
Read Start Address
Specifies as hexadecimal ASCII the unit number of the Sensor that is to be
read from. For example, to specify unit number 10, set the address to “000A”
(30303041 Hex). The read start address is always “0000” for commands that
do not require a unit number to be specified.
Bit Position
Bit access is not supported by the E3X-CIF11. This setting is always “00”.
Number of Elements
Specifies as hexadecimal ASCII the number of Units after the specified unit
number that are to be read from. The number of elements for Read ON/OFF
Data and Read Status can be set to “0001” only.
Read Data
Provides the data read in hexadecimal ASCII.
The following information describes the data format for each item.
Read Status
MRC
Variable type Read start address
Bit position
SRC
Number of elements
“01”
“01”
“00”
2 bytes
2 bytes
2 bytes
4 bytes
2 bytes
4 bytes
MRC
Response code
4 bytes
Read data
SRC
“01”
“01”
Number of elements
2 bytes
2 bytes
Bit
Contents
00
Number of Sensors connected, 2
0
01
Number of Sensors connected, 2
1
02
Number of Sensors connected, 2
2
03
Number of Sensors connected, 2
3
04
Number of Sensors connected, 2
4
05
Method for setting number of Sensors
06
Always 0.
07
Always 0.
08
Number of Sensors that can communicate, 2
0
09
Number of Sensors that can communicate, 2
1
10
Number of Sensors that can communicate, 2
2
11
Number of Sensors that can communicate, 2
3
12
Number of Sensors that can communicate, 2
4
13
Mobile Console Communications Flag
14
Sensor Communications Error Flag
15
Sensor Communications Flag
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...