42
Explicit Message Communications
Section 2-6
3.
An error will occur when performing two-point teaching or two-position
teaching if the command for the second point is sent without sending the
command for the first point/position. Send the command for the first point/
position before sending the command for the second one.
4.
The Initialize Sensor Settings command will return the settings for each
Sensor to its default value. The Sensor Reset command interrupts the
power by turning the Sensor power OFF and ON again.
2-6-5
List of Error Codes
Response
codes
Error name
Cause
08FF
Service not supported
There is an error in the service code.
09FF
Invalid attribute value
The specified attribute ID is not supported.
The write data is outside the data range.
• Threshold setting is outside setting range.
• Basic settings are outside setting range.
• Timer is not set according to restrictions.
• Hysteresis width is set outside range.
• Custom Flags are set outside range.
• Special Flags are set outside range.
• Number of Sensors connected is not set between 1 and 16.
• Number of Units monitoring incident light are not set between 1 and 16.
16FF
Object does not exist
The specified instance ID is not supported.
• Number of Units specified in instance ID is greater than number of Sensors
connected.
15FF
Too much data
Size of data is longer than specified size.
13FF
Not enough data
Size of data is shorter than specified size.
0CFF
Object state conflict
Specified command cannot be executed.
• Mobile Console is connected.
• Error has occurred in communications with Sensor.
• Sensor is not set to RUN mode.
• The command for the second point/position of a Two-point Teaching or Two-
position Teaching commands was executed without executing the command for
the first one.
• An unsupported command was sent. (For example, a Read Incident Light Level
command was sent to a Terminal Block Unit.)
20FF
Invalid parameter
The specified operation data is not supported.
0EFF
Attribute not settable
A write service code was specified for a read-only attribute ID.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...