116
DeviceNet Connection Settings
Appendix C
Changing Connections Using the Configurator
When a CS1W-DRM21 is used as the DeviceNet master, the OMRON DeviceNet Configurator (Ver. 2.10 or
higher) can be used to change the connections. The procedure is as follows:
Step 1: Connecting the Configurator
1.
Connect the DeviceNet Configurator.
The parameters of the master as well as the Fiber Amplifier Sensor Communication Unit settings can be
changed, so connect the master that will actually be used.
2.
Turn ON the power, and put the Configurator online.
3.
Upload the network configuration.
Step 2: Selecting the Group
The Fiber Amplifier Sensor Communication Unit divides IN data allocations into the following groups.
.
The data contents for each group is as follows:
1. ON/OFF Data with Status
Group
Data
Number of bytes
Connection path
1
ON/OFF data with status
Always 2 bytes.
200424013003
2
ON/OFF data
Always 2 bytes.
200424023003
3
Status data
Always 2 bytes.
200424033003
4
Incident light level data
2 bytes
number of Units moni-
tored for incident light levels
200424043003
5
ON/OFF data + status data
Always 4 bytes.
200424053003
6
Status data + incident light level data
2 bytes + (2 bytes
number of
Units monitored for incident light
levels)
200424063003
7
ON/OFF data + status data + incident
light level data
4 bytes + (2 bytes
number of
Units monitored for incident light
levels)
200424073003
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Se
ns
or C
o
m
m
u
nic
a
tion
s F
lag
Se
ns
or C
o
m
m
u
nic
a
tion
s Erro
r Fl
ag
M
o
b
ile
C
ons
ol
e C
o
mm
uni
cat
ion
s F
lag
Uni
t No
. 13
O
N
/O
F
F
da
ta
Uni
t No
. 12
O
N
/O
F
F
da
ta
Uni
t No
. 11
O
N
/O
F
F
da
ta
Uni
t No
. 10
O
N
/O
F
F
da
ta
U
n
it N
o
. 9 O
N
/O
FF
data
U
n
it N
o
. 8 O
N
/O
FF
data
U
n
it N
o
. 7 O
N
/O
FF
data
U
n
it N
o
. 6 O
N
/O
FF
data
U
n
it N
o
. 5 O
N
/O
FF
data
U
n
it N
o
. 4 O
N
/O
FF
data
U
n
it N
o
. 3 O
N
/O
FF
data
U
n
it N
o
. 2 O
N
/O
FF
data
U
n
it N
o
. 1 O
N
/O
FF
data
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...