90
CompoWay/F Message Communications
Section 4-5
Write Special Flags
Writes the following settings for the Sensor of the specified unit number. This
command is possible with E3X-DA6TW and E3X-DA8TW Sensors only. An
error will occur if this command is written for any other Sensor.
Response Codes
Normal Completion
Error Completion
Bit
Contents
00
Always 0.
01
Always 0.
02
Always 0.
03
Always 0.
04
Operating Mode Flag (one-word):
0: Dark-ON
1: Light-ON
05
Operating Mode Flag (two-word):
0: Dark-ON
1: Light-ON
06
Area Setting Flag:
0: AREA OFF
1: AREA ON
07
Always 0.
08
Always 0.
09
Always 0.
10
Always 0.
11
Always 0.
12
Always 0.
13
Always 0.
14
Always 0.
15
Always 0.
Response code
Name
Description
“0000”
Normal completion
No error has occurred.
Response
code
Error name
Cause
“1001”
Command too
long
The command is too long.
“1002”
Command too
short
The command is too short.
“1003”
Number of ele-
ments/data mis-
match
The number of data does not match the number
of elements.
“1100”
Parameter error
The write data setting is out of range.
• Threshold setting out of range.
• Basic settings are out of range.
• Timer setting is not within limits.
• Hysteresis width is out of range.
• Custom Flags are out of range.
• Special Flags are out of range.
• Number of Sensors connected is more than 16.
• Response delay time is set to more than
100 ms.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...