30
Explicit Message Communications
Section 2-6
The unit number specified by the instance ID must be set between 0001 Hex
and 0010 Hex.
Note
1.
The E39-TM1 Terminal Block Unit has no parameters that can be read, so
an error will occur if the unit number of a Terminal Block Unit is specified.
2.
An error will occur if the (Batch) Read ON/OFF Incident Light Levels com-
mand is executed when the unit number of a Unit other than an E3X-DA6-
P is specified.
3.
An error will occur if the Read Special Flags command is executed when
the unit number of a Unit other than an E3X-DA6TW or E3X-DA8TW is
specified.
The following tables and explanations provide the data format for each item.
Read ON Incident Light
Level
(See note 2.)
Specifies the unit number as
the instance ID and reads
the incident light levels when
Sensor is ON.
009C
Unit
number
04
Read OFF Incident
Light Level
(See note 2.)
Specifies unit number as the
instance ID and reads the
incident light level when
Sensor is OFF.
009C
Unit
number
05
Batch Read ON Inci-
dent Light Levels
(See note 2.)
Reads the ON incident light
levels of connected Sen-
sors in a batch.
009C
0000
68
Batch Read OFF Inci-
dent Light Levels
(See note 2.)
Reads the OFF incident light
levels of connected Sen-
sors in a batch.
009C
0000
69
Read Threshold Setting Specifies the unit number as
the instance ID and reads
the threshold value.
009C
Unit
number
11
Batch Read Threshold
Settings
Reads the threshold values
of the connected Sensors in
a batch.
009C
0000
75
Read Basic Settings
Specifies the unit number as
the instance ID and reads
basic settings.
009C
Unit
number
12
Read Timer Setting
Specifies the unit number as
the instance ID and reads
the timer.
009C
Unit
number
13
Read Hysteresis Width
Specifies the unit number as
the instance ID and reads
the hysteresis width.
009C
Unit
number
16
Read Custom Flags
Specifies the unit number as
the instance ID and reads
the Custom Flags.
009C
Unit
number
17
Read Special Flags
(See note 3.)
Specifies the unit number as
the instance ID and reads
the Special Flags.
009C
Unit
number
1C
Read Number of Sen-
sors
Reads the number of Sen-
sors connected.
009C
0000
30
Read Number of Inci-
dent Light Level Monitor
Units
Reads the number of Units
monitoring incident light lev-
els.
009D
0000
31
Explicit message
Function
Command
Class
ID
Instance
ID
Attribute
ID
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...