3 Configuration Software
3-12
CJ-series PROFINET IO Controller Unit Operation Manual for NJ-series CPU Unit (W511)
2
Using the Drag & Drop function
A Device DTM listed in the standard Device Catalogue window can be dragged and dropped
from the Device Catalogue to a desired position in the Network view.
3
Using the
Add Device
button
A device DTM selected in the Device Catalogue can be added to a selected Master DTM in the
Network view by clicking the
Add Device
button in the Device Catalogue window.
A project file, containing various DTMs, can both be saved to and opened from hard disk. To save a
project file select the
File - Save or File - Save As...
menu option. This will display the standard
Windows File selection window, allowing the user to enter a file name.
The Project File is saved with the extension *.CPR. Saving the data is initiated from CX-Configura-
torFDT, but every DTM must support the save function as well. The settings of each DTM is saved in
the Project file.
A Project file can be opened by choosing the
File - Open
menu option. This will open the standard
Windows File selection window, after which the Project file can be selected and opened.
Additional Information
When opening a Project file, the network tree view is automatically constructed.
A Project File can also be opened from Windows Explorer. Double-clicking a file with extension
*.CPR will invoke CX-ConfiguratorFDT and open the selected file.
CX-ConfiguratorFDT provides automatic generation of project documentation upon command of the
user. The documentation is generated in HTML format, and can cover either single DTMs or the
whole project. After generation of the HTML document, it will automatically launch the default Inter-
net browser, to display the result.
Exporting Projects to HTML
To export the project information to HTML either:
•
Select the
File - Export Project as HTML
option from the main menu, or
•
Select the
Export to HTML
option from the context menu. First select the project level in the Net-
work view, and then right click the mouse to display the context menu.
In both cases a window will pop up displaying the progress of the export process.
After exporting the information, the default browser is launched, showing the result of the export pro-
cess. The HTML file contains links to open the information pages for the individual DTMs. The
amount of the information displayed depends on the individual DTMs. The displayed information can
range from only the device type and version information to up to all possible settings and selections
made for the device.
Exporting DTM Information to HTML
To export single DTM information to HTML execute the following steps:
1
Select the DTM in the Network view.
3-2-3
Saving and Opening Projects
3-2-4
Exporting to HTML