DM Area Allocation in Linear and Circular Modes
Section 5-2
m+19
00 to 15
m+20 to
m+24
Output pattern and lower and upper limits of range 1
Refer to the information on the settings of range 0.
m+25 to
m+29
Output pattern and lower and upper limits of range 2
Refer to the information on the settings of range 0.
m+30 to
m+34
Output pattern and lower and upper limits of range 3
Refer to the information on the settings of range 0.
m+35 to
m+39
Output pattern and lower and upper limits of range 4
Refer to the information on the settings of range 0.
m+40 to
m+44
Output pattern and lower and upper limits of range 5
Refer to the information on the settings of range 0.
m+45 to
m+49
Output pattern and lower and upper limits of range 6
Refer to the information on the settings of range 0.
m+50 to
m+54
Output pattern and lower and upper limits of range 7
Refer to the information on the settings of range 0.
m+55 to
m+59
Output pattern and lower and upper limits of range 8
Refer to the information on the settings of range 0.
m+60 to
m+64
Output pattern and lower and upper limits of range 9
Refer to the information on the settings of range 0.
m+65 to
m+69
Output pattern and lower and upper limits of range 10
Refer to the information on the settings of range 0.
m+70 to
m+74
Output pattern and lower and upper limits of range 11
Refer to the information on the settings of range 0.
m+75 to
m+79
Output pattern and lower and upper limits of range 12
Refer to the information on the settings of range 0.
m+80 to
m+84
Output pattern and lower and upper limits of range 13
Refer to the information on the settings of range 0.
m+85 to
m+89
Output pattern and lower and upper limits of range 14
Refer to the information on the settings of range 0.
m+90 to
m+94
Output pattern and lower and upper limits of range 15
Refer to the information on the settings of range 0.
m+95 to
m+99
---
Not used.
Word
Bit
Function
Output pattern of range 0 (1: ON; 0: OFF)
Set bits to 1 so that signals will be output from the bits when the count value is between the upper
and lower limits. The internal outputs will be transferred to word n+9. The external outputs will be
turned ON when word n bit 07 is set to 1.
External
outputs
Internal outputs
To output pins 0 to 7 of the output connector