141
Data Area Allocation
Appendix B
Note
Values in brackets are in hexadecimal.
Preset Value Range
Values in parentheses are for counter 2 and values in brackets are in hexa-
decimal.
IR Bit Allocation
(n = 100 + 10 x Unit No.) or
(n = 400 + 10 x (Unit No. -
10) if Unit No. is A to F)
m+38
External output 6 OFF count value
x10
3
[x16
3
]
x10
2
[x16
2
]
x10
1
[x16
1
]
x10
0
[x16
0
]
m+39
External output 6 OFF count value
0 [0]
x10
6
[0]
x10
5
[x16
5
]
x10
4
[x16
4
]
m+40
External output 7 ON hold time (Unit: 1 s)
FFFF: ON hold
x10
1
x10
0
x10
–1
x10
–2
m+41 to m+49
Not used.
m+50 to m+89
Counter preset value 0
to 19
Counter preset value (0 to 8,388,607)
x10
3
[x16
3
]
x10
2
[x16
2
]
x10
1
[x16
1
]
x10
0
[x16
0
]
0 [0]
x10
6
[0]
x10
5
[x16
5
]
x10
4
[x16
4
]
m+90 to m+99
Not used.
DM
15
00
Preset value
Range
External output ON/OFF
value
(Words m+10 to m+20)
(Words m+30 to m+40)
External output 0 (4)
0 to 8,388,606
[000000 to 7FFFFE]
External output 1, 2 (5, 6)
0 to 8,388,607
[000000 to 7FFFFF]
Counter preset value
(Words m+50 to m+89)
1 to 8,388,607
[000001 to 7FFFFF]
Counter 2 does not start if this value is set to 0.
Bit
Word (Output)
n
n+1
00
START Counter 1
Counter 1 preset value number
x10
0
01
START Counter 2
02
Not used.
03
Data transfer
04
RESET Counter 1
Counter 1 preset value number
x10
1
05
RESET Counter 2
06
Read error
07
ENABLE External Output
08
0
Forced external output
1: ON, 0: OFF
Counter 2 preset value number
x10
0
09
1
10
2
11
3
12
4
Counter 2 preset value number
x10
1
13
5
14
6
15
7
Содержание C200H-CT021
Страница 1: ...C200H CT021 High speed Counter Unit Operation Manual Revised December 2000 ...
Страница 2: ...iv ...
Страница 4: ...vi ...