Страница 1: ...wh Münzprüfer Dietmar Trenner GmbH Teltower Damm 276 D 14167 Berlin Version 1 5 Technical Manual ELECTRONIC COIN SELECTOR EMP 500 xx v4 ...

Страница 2: ...ion of information contained in this manual wh Münzprüfer will not be liable for any consequential loss or damage howsoever caused This manual is protected by copyright and all rights are reserved Without prior authorisation by wh Münzprüfer no part of this manual may be reproduced in any form by photocopy microfilm or other processes nor may it be transmitted in any form usable by data processing...

Страница 3: ...Coin Selector 7 2 1 Introduction 7 2 2 Programming of Coins 9 2 2 1 Calibration 9 2 2 2 Cloning Programming without Coins 12 2 3 Coin Selector Output Signals 13 2 3 1 Inventory Impulse Option I 14 2 4 Coin Blocking 15 2 4 1 General Blocking Option M 15 2 4 2 Individual Coin Blocking via DIP switches 15 2 5 Coin Values 16 2 6 Slave Channels 18 2 7 Coin Return 18 2 8 Safety Features 18 2 8 1 Coin on...

Страница 4: ...ls and has 2 output lines Coin output assignment to the output lines can be freely programmed EMP 500 00 v4 open collector outputs 30 V 30 mA UCEsat 800 mV EMP 500 01 v4 solid state relay outputs 230 V AC 600 mA EMP 500 04 galvanised separated infra red optocoupler outputs output transistors closed in standby 35 V 20 mA UCEsat 100 mV maximum potential difference 350 V DC EMP 500 12 v4 galvanised s...

Страница 5: ...v4 subject to technical modification page 5 27 The electronic coin selector EMP 500 xx v4 is available with the following front plates Front plate F503 117 x 60 mm height x width Front plate F70 5 92 25 x 57 mm Front plate F94 5 101 x 88 5 mm EMP 500 with Front Plate F 70 5 EMP 500 with Front Plate F 503 ...

Страница 6: ...d to any of the 16 master coin channels through programming Please note that the number of coin pulses per coin can be freely programmed as well output pulse length 50 ms 2 to 10 seconds programmable pulse pause interval programmable supply voltage 11 V to 24 V AC DC power supply Maximum 0 6 W standby during coin acceptance 4 5 W for approx 100 ms temperature range 10 C to 70 C humidity classifica...

Страница 7: ...assumes that the wheasy 2 programming manual and the programming software are available and that the operator is familiar with them References here to wheasy 2 software are only made relative to its specific application to the particular coin selector and its functions To power up the EMP 500 v4 and the associated PC interface we strongly recommend our N 780 power supply for this purpose The power...

Страница 8: ... the serial number The coin selector must be read out first and this procedure is explained in the wheasy 2 manual Please also note the information on the coin selector decal It is important that the coin selector be located in an upright stance when programming Similarly the bottom surface of the coin selector needs to be horizontal This can often be achieved by mounting the coin selector in the ...

Страница 9: ...uired via the internet from wh Münzprüfer The wheasy 2 cloning function also allows the transfer of a data set from a factory set coin selector to any electronic coin selector in the same series In this way identical programming may be duplicated for all units as required especially for new currencies 2 2 1 Calibration 2 2 1 1 Calibration Using wheasy 2 Under the Edit pull down menu is the functio...

Страница 10: ... how the coin set used for calibration is typical of the coins currently in circulation The number of inserted coins as well as the overall number of coins required is shown in the calibration window The total number of required coins is determined by the data file Calibration automatically ends once the required number of coins have been inserted and the procedure may now be finished or another c...

Страница 11: ...d via blocking switch no 8 ON 3 If blocking switch no 7 is activated additionally ON teaching is effected using narrow tolerances 4 The blocking switches 15 and 16 are used to teach coin channels 15 and 16 The switches have to be set to the OFF position when activating the teach mode otherwise the coin selector software blocks the two channels for the teach mode 5 If any coin blocking switches are...

Страница 12: ...ored in the PC As a prerequisite to cloning it is necessary for the coin measuring system of the originating coin selector to be the same as the measuring system of the target coin selector wheasy 2 automatically compares the measuring configuration of the attached coin selector with the measuring configuration of the coin selector that produced the coin parameter set Cloning is only accomplished ...

Страница 13: ...ultiple output channels and that the number of pulses can be freely configured for each coin channel One and the same output line or a combination of the output lines can be assigned to several coin channels The 16 slave channels always have the same output channel s as the associated master channel The coin selector signals gives the corresponding number of pulses on the respective output channel...

Страница 14: ...utput should be open or closed in standby This is essential for the configuration of the infrared optocoulper output lines 2 3 1 Inventory Impulse Option I The EMP 500 v4 may be programmed to release an inventory or credit impulse This inventory impulse is intended for the counting and logging of accepted coins The impulse length and impulse pause are separately programmable in the range of 1 to 2...

Страница 15: ...he possible combinations of the above two options selected check box Infrared optocoupler input general blocking with 0 general blocking with an open input powered not powered X X X Table 1 The function of general blocking in relationship to the programmed mode of the coin selector As the EMP 500 v4 has an infrared optocoupler only the two recommended settings are shown in Table 1 Note Please info...

Страница 16: ...This value may be used for the inventory impulses Most importantly programming the coin values display a check on what is already programmed in coin selector including channel assignments 16 different coin values can be programmed into the master channels The slave channels always have the same coin value as the master channel The Coin Values selection is available under the Edit pull down menu Th...

Страница 17: ...ch teach mode function for a channel This mode is activated when the appropriate box shows a From the series v4 onwards a star may be shown to the left of the TM checkbox The star indicates that this master channel also has a slave channel associated with it See section 2 6 There are some special fields at the bottom of the window below the heading of Scaling These adjustable parameters have the f...

Страница 18: ...or EMP 500 v4 has a feature which will measure and give credit for a coin and then return it This feature can be used for example with test tokens It can also be used where certain persons for example employees are to receive benefits without cost e g car parking The setting of this function is also discussed in the wheasy 2 manual in the Edit chapter under the sub heading Sorting Shafts 2 8 Safet...

Страница 19: ...ming and a normal receipt signal as it can recognise the different width and or identify a combination of simultaneously arranged coin output lines The following coin jam signals are possible Coin jam 1 in the measurement system Coin jam 2 not used on EMP 500 v4 Coin jam 3 between the measurement system and the acceptance light barrier Coin jam 4 in the acceptance light barrier Coin jam 5 not poss...

Страница 20: ...ng switch which has to be used to activate the teach mode for this channel Blocking switch for the broad channel Blocking switch for the narrow channel Blocking switch for the very narrow channel Blocking switch for a coin type or coin group currency Output line 4 Maintenance The EMP 500 v4 is an extraordinarily robust coin selector and operates relatively maintenance free However it should be cle...

Страница 21: ...re still in the process of being developed have applied up to now for finished products and their bringing into circulation Tests are effected according to the EMC regulations which means certification of electromagnetic compatibility and if applicable of interference emission The tests have been realized according to EN 50082 1 and EN 50081 1 These tests grant that electronic coin selectors of ty...

Страница 22: ...4 3 coin 1 green GND GND 12 to 24V AC DC black 10K GND option VCC GND control 1 2 4 3 30V DC 30 mA Figure 11 Connecting diagram EMP 500 00 v4 EMP 500 01 v4 S26MD01 1 2 3 4 5 6 8 main blocking orange 2 1 4 3 I 0 5 mA AC DC 1 2 4 3 approx 100 msec during coin acceptance 12 to 24V AC DC black S26MD01 1 2 3 4 5 6 8 coin 2 or inventory grey GND coin 1 blue 230 V AC 600 mA coin 2 or inventory violet mai...

Страница 23: ...ec during coin acceptance GND 35 V DC 20 mA option GND 35 V DC 20 mA 1 2 4 3 coin 2 or Inventory normaly open blue I 0 5 mA AC DC Figure 13 Connecting diagram EMP 500 04 v4 coin 1 normally closed white coin 2 or inventory normally closed red GND coin 1 normally closed red PC815 1 2 3 4 approx 100 msec during coin acceptance I 0 5 mA AC DC GND 2 1 4 3 control 35 V DC 30 mA EMP 500 12 v4 GND 12 to 2...

Страница 24: ...to 24 V AC DC 0 6 W 4 5 W GND 2 1 4 3 main blocking orange 12 to 24V AC DC yellow control option I 0 5 mA AC DC coin 1 normally closed blue GND GND coin 2 or inventory normally closed grey approx 100 msec during coin acceptance coin 1 normally closed brown EMP 500 14 v4 GND 35 V DC 30 mA PC815 1 2 3 4 PC815 1 2 3 4 main blocking orange 12 to 24V AC DC yellow 35 V DC 30 mA Figure 15 Connecting diag...

Страница 25: ...wh Münzprüfer Dietmar Trenner GmbH Germany Technical Manual EMP 500 xx v4 Version 1 51 EMP8x0 00 04 13 v4 subject to technical modification page 25 27 Figure 16 Dimensions of EMP 500 on F70 5 Frontplate ...

Страница 26: ...f US and Canadian Dollars as well as two tokens for on site programming Programming pulse length 50 ms pulse pause 100 ms coins blocking switch no wide mid narrow number of pulses output line notes 0 25 USD 1 2 1 1 1 00 USD 5 6 4 1 total blocking of USD via switch number 14 0 25 CAD 1 2 1 1 0 50 CAD 3 4 2 1 1 00 CAD 5 6 9 4 1 2 00 CAD 10 11 8 1 total blocking of CAD via switch number 13 STD 118 1 ...

Страница 27: ...ll as two tokens for on site programming Programming pulse length 50 ms pulse pause 100 ms coins blocking switch no wide mid narrow number of pulses output line notes 0 10 GBP 1 2 1 1 0 20 GBP 1 2 2 1 0 50 GBP 1 3 5 1 1 00 GBP 4 5 6 10 1 2 00 GBP 4 5 7 20 1 total blocking of GBP via switch number 14 STD 118 1 880 15 1 1 teach mode channel 0 10 EUR 9 10 1 2 0 20 EUR 9 10 2 2 0 50 EUR 9 10 5 2 1 00 ...