44292401TH Rev.1
48 /
Oki Data CONFIDENTIAL
COMPOSITION/OPERATION
17.2 Drive
A0HFT2C509AA
Transport motor
Fusing roller
17.2 Drive
17.3 Operation
17.3.1
Fusing temperature control
17.3 Operation
17.3.1
Fusing temperature control
• To fuse the toner image on the media (image yet to be permanently fixed) properly into
the media, the heater lamps are turned O
N
and OFF as necessary to bring the fusing
temperature to an appropriate level.
• Thermistors are used to detect the surface temperature of the Fusing roller. The heater
lamps are then turned O
N
and OFF as necessary to achieve the set temperature.
A. Warm-up control
Control is provided until the Fusing roller reaches the predetermined level.
B. Control start timing
• The power switch is turned O
N
.
• A malfunction or media misfeed is reset.
• The main body leaves the power save mode.
• A door is closed.
C. Control termination timing
• The Fusing roller reaches a predetermined temperature.
• A malfunction or media misfeed is reset.
• A door is opened.
A011T2C544AA
Warm-up control
Wait control
Print control
Wait control
Printing
temperature
Warm-up
complete
temperature
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...