ADJUSTMENT/SETTING
15.3.11 SOFT SWITCH: #11
• Bit 6: If this bit set to 1, not allowed user to select pulse dial, and this function open ser-
viceman to change.
• Bit 5: Bit set to 1, LCD will show the command between each party, the detail specifica-
tion see service mode specification.
Bit No.
Designation
Function
Initial
Setting
Bit HEX
8
Reserved
Reserved
0
2
7
Detect dial tone after
pre-fix number
0: No
0
1: Yes
6
Pulse dial allowed to
select
0: Yes
1
1: Not allowed
5
Protocol signal display
mode
0: Not to display
0
1: Display V8 or T30 command within communication.
4
Reserved
Reserved
0
0
3
0
2
USB port number
fixed
0: OFF
0
1: ON
1
DTMF low frequency
compensation
0: Base on SW23 (1 to 4)
0
1: High 0.5 dB
15.3.12 SOFT SWITCH: #12
• Bit 1-2: Delay time from FSK mode to PSK mode, this use for G3 mode only, V.34 do not
need this setting.
• Bit 6-7: If counter equal “1”, machine will down to next lower speed for next data phase.
Bit No.
Designation
Function
Initial
Setting
Bit HEX
8
ECM mode capability
1: Yes
1
8
0: No - also disable V.34 modem capability
7
V.34 fall back counter
for V.34 TX
0
6
0
5
Send CTC after 4th
PPR
0: Send CTC (Continue To Correct)
0
1: Send EOR (End Of Transmission)
4
Reserved
Reserved
0
0
3
Send EOR after low-
est speed
0: Send DCN (Re-dial)
0
1: Send EOR_xxx [Germany PTT]
2
TCF transmission tim-
ing after DCS signal
0
1
0
Counter
1
2
3
4
Bit No. 7
0
0
1
1
Bit No. 6
0
1
0
1
Description (ms)
70
80
90
100
Bit No. 2
0
0
1
1
Bit No. 1
0
1
0
1
14.3.11
SOFT SWITCH: #11
14.3.12
SOFT SWITCH: #12
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...