44292401TH Rev.1
157 /
Oki Data CONFIDENTIAL
ADJUSTMENT/SETTING
15.3.19 SOFT SWITCH: #19
15.3.20 SOFT SWITCH: #20
Bit No.
Designation
Function
Initial
Setting
Bit
HEX
8
CNG signal level
0
6
7
1
6
1
5
0
4
DTMF high frequency
level
1
8
3
0
2
0
1
0
Level (dBm) -17
-16
-15
-14
-13
-12
-11
-10
Bit No. 8
0
0
0
0
0
0
0
0
Bit No. 7
0
0
0
0
1
1
1
1
Bit No. 6
0
0
1
1
0
0
1
1
Bit No. 5
0
1
0
1
0
1
0
1
Level (dBm) -9
-8
-7
-6
-5
-4
-3
-2
Bit No. 8
1
1
1
1
1
1
1
1
Bit No. 7
0
0
0
0
1
1
1
1
Bit No. 6
0
0
1
1
0
0
1
1
Bit No. 5
0
1
0
1
0
1
0
1
Level (dBm) -17
-16
-15
-14
-13
-12
-11
-10
Bit No. 4
0
0
0
0
0
0
0
0
Bit No. 3
0
0
0
0
1
1
1
1
Bit No. 2
0
0
1
1
0
0
1
1
Bit No. 1
0
1
0
1
0
1
0
1
Level (dBm)
-9
-8
-7
-6
-5
-4
-3
-2
Bit No. 4
1
1
1
1
1
1
1
1
Bit No. 3
0
0
0
0
1
1
1
1
Bit No. 2
0
0
1
1
0
0
1
1
Bit No. 1
0
1
0
1
0
1
0
1
Bit No.
Designation
Function
Initial
Setting
Bit
HEX
8
Reserved
Reserved
0
0
7
0
6
0
5
0
4
0
0
3
0
2
0
1
0
15.3.21 SOFT SWITCH: #21
• Bit 1-2: T1 indicate the calling time after dialing, can adjust the T1 time more long by change the
default value. The default T1 timer depends on each country regulation.
• Bit 3: Some old machine can not accept DIS command over 4 bytes, and every time will become
fail. In this case can set this bit to 1. If this bit set to 1, JBIG and V8 capability will disable auto-
matically.
• Bit 8: Sender machine’s name will show on the other party’s LCD or print on the report if remote side
is the same model.
Bit No.
Designation
Function
Initial
Setting
Bit HEX
8
NSS signal before
DCS
0: Not to send NSS signal for self mode in TX mode
1
8
1: Send NSS signal if remote side is same model
7
CNG sending duration
after dialing
0
6
0
5
T4 timer
0: 3.0 sec. Normal case
0
1: 4.5 sec.
4
VOIP
(Voice over IP)
0: Disable
0
0
1: Enable
3
DIS signal length
0: Normal length (Bit 1 to 64)
0
1: 4 bytes DIS command. bit 1 to 32 only
2
Increase default T1
timing during calling
(Only for TX function)
0
1
0
Duration (unit=sec)
40
60
70
120
Bit No. 7
0
0
1
1
Bit No. 6
0
1
0
1
Description (sec)
T1
T1 + 30 T1 + 40 T1 + 60
Bit No. 2
0
0
1
1
Bit No. 1
0
1
0
1
14.3.19
SOFT SWITCH: #19
14.3.20
SOFT SWITCH: #20
14.3.21
SOFT SWITCH: #21
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...