ADJUSTMENT/SETTING
(2) V.34 Communication (example)
A0FDF3C508DA
NAME:TMFP
TEL :886 3 4733507
DATE:APR.10.2008 12:20
SESSION FUNCTION NO.
DESTINATION STATION
DATE
TIME
PAGE DURATION MODE RESULT
0001
TX
010
27187480
OCT.27 17:19
008 00h00min03s ECM
-33.6
OK
TX
RX
DATA
CM
CJ
DCS
►
PIX
PPS-EOP
DCN
ANS
JM
NSF
NSF
CSI
DIS
CFR
MCF
FF 03 20 00 00 25 00 00 00 12 10 6D 02 00 58 00 28 B8 A4 A0 80 91 60
FF 03 20 00 00 25 01 45 43 4E 45 59 45 4B
FF 03 40 30 38 34 37 38 31 37 32 20 20 20 20 20 20 20 20 20
FF 13 80 20 EE A8 C4 80 98 81 80 80 60
FF 13 83 00 02 F0 84 80 80 80 80 80 20
FF 13 84
FF 13 BF 2F 00 00 7F
FF 13 8C
FF 13 FB
PROTOCOL MONITOR REPORT
V.8 PROTOCOL DUMP
14.10 ADMIN. REGISTRATION
14.11 FIXED ZOOM CHANGE
• Default fixed zoom ratios and setting ranges according to marketing area
<Metric>
<Inch>
14.12 FACTORY TEST
• This test is for factory adjustment only and should NOT be used.
Function
• Use to display or change the current Administrator number.
Use
Setting/
procedure
• Administrator number: 000000 to 999999
1.
Enter the [SER
V
ICE MODE].
2.
Select [ADMIN. REGISTRATION] and press the Select key.
3.
Check that the current ADMIN. No. is displayed and then press the [Back] key.
4.
Enter the new ADMIN. No. from the 10-key pad and press the Select key.
Function
• The fixed zoom ratios can be changed.
Use
Setting/
procedure
1.
Enter the [SER
V
ICE MODE].
2.
Select [FIXED ZOOM CHANGE] and press the Select key.
3.
Select the fixed zoom ratio that you wish to change and press the Select key.
4.
Use the 10-Key Pad to type in the desired fixed zoom ratio.
Setting name
Initial fixed zoom ratio
Setting range
REDUCTION2
70%
51% to 70%
REDUCTION1
8
1%
71% to 99%
EXPANSION1
115%
101% to 140%
EXPANSION2
141%
141% to 199%
Setting name
Initial fixed zoom ratio
Setting range
REDUCTION2
64%
51% to 64%
REDUCTION1
78
%
65% to 99%
EXPANSION1
129%
101% to 153%
EXPANSION2
154%
154% to 199%
Functions/Use
SIGNAL TEST
• This test is for factory adjustment only and should NOT be used.
RELAY TEST
• This test is for factory adjustment only and should NOT be used.
SENSOR TEST
• This test is for factory adjustment only and should NOT be used.
DIAL TEST
• This test is for factory adjustment only and should NOT be used.
V
OLUME TEST
• To check the volume of the speaker.
PANEL BUZZER TEST
• To check the operation of the display and all indicators and buttons.
• When the panel buzzer test are finish, press the panel reset key twice.
RAM TEST
• To test reading and writing of the memory.
13.10 ADMIN. REGISTRATION
13.11 FIXED ZOOM CHANGE
13.12 FACTORY TEST
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...