44292401TH Rev.1
138 /
Oki Data CONFIDENTIAL
ADJUSTMENT/SETTING
Soft Switch No.
Bit No.
Designation
Page No.
#30
8/7
Pause delay time within digits
P.161
6/5/4/3/
2/1
Signal tone insensitivity (dBm) after dial for busy tone
#31
7/6/5
Min re-dial interval
P.162
4/3/2/1
Max. re-dial attempts
#32
—
Reserved
P.162
#33
7
V.17 Echo protection tone
P.162
6
V.29 Echo protection tone
5
Compromise equalize enable (CEQ) in the transmit path (TCEQ)
4
Compromise equalize enable (CEQ) in the receiver path (RCEQ)
#34
—
Reserved
P.162
#35
8/7
Dial tone table switch time
P.163
6/5/4 Dial tone frequency upper range index
3/2/1
Dial tone frequency low range index
#36
8
Re-dial attempts continue fail counter (Using for detect line prob-
lem error)
P.163
4/3/2/1
Re-dial attempts fail limitation counter (Using for detect line prob-
lem error)
#37
7
Auto dial learning for V.34 modem
P.164
6/5/4 RX start symbol rate for V.34 modem
3/2/1
TX start symbol rate for V.34 modem
#38
7
Set/Reset V.34 transmit level deviation
P.164
6/5
V.34 flag number between ECM frame
4
Phase 2 guard tone power level (V.34)
1
V.8 /V.34 capability
#39
8
Disable V.34 TX for V.34 modem
P.164
7
Disable V.34 RX for V.34 modem
6/5
Flags number in FSK frame for V.34 modem
4
Manual TX mode for V.34 modem
3
Switch from V.17 to V.34 if DIS Bit 6 set after received DIS
2/1
Delay time in primary channel for V.34 transmit after CFR or
MCF signal
#40
8/7/6/5
V.17 RX start speed select receiving start speed for V.17
P.165
3/2/1
V.34 RX start speed prohibit V.34 mode when upper speed less
#41
8/7/6/5
V.17 TX start speed select receiving start speed for V.17
P.165
3/2/1
V.34 TX start speed prohibit V.34 mode when upper speed less
#42
8/7/6/5/
4/3/2/1
Reserved
P.166
#43
8/7/6/5/
4/3/2/1
Reserved
P.166
#44
—
Reserved
P.166
Soft Switch No. Bit No.
Designation
Page No.
#45
5
Call transfer
P.166
4/3/2/1 No. of call transfer
#46
8
Daylight savings timer
P. 166
4
RX print mode
3
Default TX mode
2
Header for FAX TX
1
Print model name on top of TX page if name not register
#47
6
RX mode
P.167
5
Footer
#48
8
Activity report
P. 167
7/6 TX result report
5/4
RX result report
#49
5
Re-dial method if Comm. Fail
P.167
4/3/2/1 No. of rings
#50
8
Transmit or cancel after time out in “Memory TX”
P.167
#51
4/3
T30 monitor report selection
P. 168
2
Send unsent page mode for memory transmission
#52
—
Reserved
P. 168
#53
—
Reserved
P. 168
#54
8
Report Date/Time type
P. 168
7/6
Report Date/Time format
5/4
Memory near full capacity for Fax and I-Fax scanning
3/2
Memory near full capacity for N-Scan scanning
#55
—
Reserved
P. 169
#56
—
Reserved
P. 169
#57
—
Reserved
P.169
#58
8
Time out from PSK to FSK delay time
P. 169
#59
6/5/4/
3/2/1
Time Between GMT (Greenwich Mean Time)
P.170
#60
6
Quick memory TX
P.171
2 Off hook alarm after communication
1
Display destination selection within TX phase C
#61
4/3/2/1 Max. No. of ring
P.171
#62
—
Reserved
P. 172
#63
8
“#” key definition in PBX mode
P. 172
2 Fax TX image adjust
1
TX result report with image
#64
6
Print RX error report in RX side if no any FAX signal detected
P.172
5
10 PPS & 20 PPS selectable by user
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...