44292401TH Rev.1
175 /
Oki Data CONFIDENTIAL
ADJUSTMENT/SETTING
DIS (DTC) / DCS Bit Allocation Table of FIF (Facsimile Information Field)
Bit
No.
Designation
DIS/DTC
DCS
1
“0”= Invalid
“1”= Store-and-forward switching Internet fax simple mode
2
Set to “0”
3
“0”= Invalid
“1”= Real-time Internet fax
4
Set to “0”
5
Set to “0”
6
“0”= Invalid
“1”= V.8 capabilities
Invalid
7
Flame size
“0” = 256 octets preferred
“1”= 64 octets preferred
Invalid
8
Set to “0”
9
“0”= Invalid
“1”= Ready to transmit a facsimile document (polling)
Set to “0”
10
“0”= Invalid
“1”= Receiver fax operation
11
Data signalling rate
12
13
14
15
“0”= Invalid
“1”= R8
u
7.7 lines/mm and/or 200
u
200 pels/25.4 mm
16
“0”= Invalid
“1”= Two-dimensional coding capability
“0”= Invalid
“1”= Two-dimensional coding
Bit No.
Data signalling rate
14 13 12 11
0
0
0
0
V.27
ter
fall-back
mode
0
0
0
1 Rec. V.29
0
0
1
0 Rec. V.27
ter
0
0
1
1
Rec. V.27
ter
and
V.29
0
1
0
0 Not used
0
1
0
1 Not used
0
1
1
0 Reserved
0
1
1
1 Reserved
1
0
0
0 Not used
1
0
0
1 Not used
1
0
1
0 Reserved
1
0
1
1
Rec. V.27
ter
, V.29,
V33 and V.17
1
1
0
0 Not used
1
1
0
1 Not used
1
1
1
0 Reserved
1
1
1
1 Reserved
Bit No.
Data signalling rate
14 13 12 11
0
0
0
0
2400 bit/s,
rec. V.27
ter
0
0
0
1
9600 bit/s,
rec. V.29
0
0
1
0
4800 bit/s,
rec. V.27
ter
0
0
1
1
7200 bit/s,
rec. V.29
0
1
0
0 Invalid
0
1
0
1 Reserved
0
1
1
0 Invalid
0
1
1
1 Reserved
1
0
0
0
14,400 bit/s,
rec. V.17
1
0
0
1
9,600 bit/s,
rec. V.17
1
0
1
0
12,000 bit/s,
rec. V.17
1
0
1
1
7,200 bit/s,
rec. V.17
1
1
0
0 Reserved
1
1
0
1 Reserved
1
1
1
0 Reserved
1
1
1
1 Reserved
17
Recording width
capabilities
18
19
Recording length
capability
20
21
22
23
24
Extension field
“0”= Without
“1”= With
25
Reserved
26
“0”= Invalid
“1”= Un-compressed mode
27
“0”= Invalid
“1”= ECM
28
Set to “0”
Frame size 0: 256 octets
Frame size 1: 64 octets
29
Set to “0”
30
Set to “0”
Bit
No.
Designation
DIS/DTC
DCS
Bit No.
Data signalling rate
18 17
0
0
Scan line length 215 mm
r
1%
0
1
Scan line length 215 mm
r
1%
and scan line length 255
mm
r
1%
1
0
Scan line length 215 mm
r
1%
and scan line length 255
mm
r
1%
and scan line length 303
mm
r
1%
1
1 Invalid
Bit No.
Data signalling rate
18
17
0
0
Scan line length 215
mm
r
1%
0
1
Scan line length 255
mm
r
1%
1
0
Scan line length 303
mm
r
1%
1
1
Invalid
Bit No.
Recording length capability
20 19
0
0 A4 (297 mm)
0
1
A4 (297 mm) and B4 (364
mm)
1
0 Unlimited
1
1 Invalid
Bit No. Recording length capabil-
ity
20 19
0
0 A4 (297 mm)
0
1 B4 (364 mm)
1
0 Unlimited
1
1 Invalid
Bit No.
Minimum scan line time
capability at the receive
23 22 21
0
0
0
20 ms at 3.85 1/mm: T 7.7 = T 3.85 20
ms
0
0
1 5 ms at 3.85 1/mm: T 7.7 = T 3.85
0
1
0
10 ms at 3.85 1/mm: T 7.7 = T 3.85 10
ms
0
1
1 20 ms at 3.85 1/mm: T 7.7 = 1/2 T 3.85
1
0
0
40 ms at 3.85 1/mm: T 7.7 = T 3.85 40
ms
1
0
1 40 ms at 3.85 1/mm: T 7.7 = 1/2 T 3.85
1
1
0 10 ms at 3.85 1/mm: T 7.7 = 1/2 T 3.85
1
1
1 0 ms at 3.85 1/mm: T 7.7 = T 3.85
Bit No.
Minimum scan line time
23 22 21
0
0
0 20 ms
0
0
1 5 ms
0
1
0 10 ms
1
0
0 40 ms
1
1
1 0 ms
Содержание MC160MFP
Страница 1: ...MC160MFP Maintenance Manual 011710A...
Страница 18: ...44292401TH Rev 1 17 Oki Data CONFIDENTIAL MC160n Main body THEORY OF OPERATION...
Страница 55: ...44292401TH Rev 1 54 Oki Data CONFIDENTIAL Auto Document Feeder Unit THEORY OF OPERARTION...
Страница 61: ...44292401TH Rev 1 60 Oki Data CONFIDENTIAL MC160n Main body FIELD SERVICE...