DC Power Cable
Tools Required
11mm socket and wrench
1. Gently turn NuStep onto its left
side.
Jack hole Power cable jack
Remove nut and lockwasher with
11mm socket from the outside of the
cover (not shown).
Push jack through the hole in the frame
on the inside of the cover (as shown).
3. Remove wiring from clips (there
may be more clips than shown).
4. Unplug power cable from board.
Unsnap connector end of power cable
from connector pins on PCB board.
42019 DC Power Cable 5-01-05
58
The TRS 4000 is very heavy; it weighs
205 lbs (93 kg). To avoid injury, or
damage to the product, always obtain
assistance to move this product. Use
proper lifting technique.
CAUTION
!
2. Remove power cable.