NOVUS AUTOMATION
33/48
RS485 MODBUS COMMUNICATION PORT CONFIGURATION REGISTERS
Address
Description
R/W
Min.
Max.
Default
Min.
Max.
Default
184
Baud rate
RW
0
7
4
0
7
4
185
Parity
RW
0
2
0
0
2
0
186
Slave address
RW
1
247
1
1
247
1
187
Defines the variable of the third line of the
HMI
RW
0
7
0
0
7
0
Table 58
– RS485 Modbus Communication Port Configuration Registers
OFFSET REGISTERS
Address
Description
R/W
Min.
Max.
Default
Min.
Max.
Default
192
Temperature Offset
RW
-50
50
0
-90
90
0
193
Humidity Offset
RW
-50
50
0
-50
50
0
200
Pressure value used for calculations
RW
0
10000
1013
0
10000
147
Table 59
– Offset Registers
FORCING REGISTERS
Address
Description
R/W
Min.
Max.
Default
Min.
Max.
Default
201
Enables output 1 forcing
RW
0
1
0
0
1
0
202
Forced value for output 1
RW
Limits depend on the analog output 1 configuration.
203
Enables output 2 forcing
RW
0
1
0
0
1
0
204
Forced value for output 2
RW
Limits depend on the analog output 2 configuration.
205
Enables forcing of alarm 1
RW
0
1
0
0
1
0
206
Changes alarm status
RW
0
1
0
0
1
0
207
Enables forcing of alarm 2
RW
0
1
0
0
1
0
208
Changes alarm status
RW
0
1
0
0
1
0
209
Turning backlight on
RW
0
2
1
0
2
1
211
Enables buzzing forcing
RW
0
1
0
0
1
0
212
Buzzer activation
RW
0
1
0
0
1
0
213
Enables humidity forcing
RW
0
1
0
0
1
0
214
Forced humidity value
RW
0
1000
0
0
1000
0
215
Enables temperature forcing
RW
0
1
0
0
1
0
216
Forced temperature value
RW
-400
1000
0
-400
2120
0
Table 60
– Forcing Registers
MINIMUM AND MAXIMUM PSYCHROMETRIC PROPERTIES AND SECOND KEY FUNCTION RESET REGISTERS
Address
Description
R/W
Min.
Max.
Default
Min.
Max.
Default
217
Reset
of all min. and max. values
RW
0
1
0
0
1
0
221
Second function of key
RW
0
2
0
0
2
0
222
Second function of key
RW
0
1
0
0
1
0
Table 61
– Minimum and Maximum Psychrometric Properties and Second Key Function Reset Registers
DEVICE TAG REGISTERS
Address
Description
R/W
Min.
224
Device name string
RW
ASCII
CHARACTER 2
CHARACTER 1
225
RW
ASCII
CHARACTER 4
CHARACTER 3
226
RW
ASCII
CHARACTER 6
CHARACTER 5
227
RW
ASCII
CHARACTER 8
CHARACTER 7
228
RW
ASCII
CHARACTER 10
CHARACTER 9
229
RW
ASCII
CHARACTER 12
CHARACTER 11
230
RW
ASCII
CHARACTER 14
CHARACTER 13