58
DL-V3 Firmware Reference Manual Rev 2
Chapter 2
DL-V3 Commands
2.30 METTEMP
Specify Air Temperature
The
mettemp
command allows you to specify ambient temperature. Temperature specified with the
mettemp
command does not affect receiver operation. Rather, it allows you to create a record of
atmospheric conditions for post-processing purposes.
The
mettemp
set
command specifies air temperature at
temp
. This command only stores the
temperature in volatile memory, and does not automatically generate a record. The temperature can
then be displayed/recorded by requesting the
met
log.
The
mettemp
clear
and the
mettemp
default
commands clear the temperature setting
.
The
mettemp
default
command clears the temperature setting.
Syntax
mettemp
set [
temp
]
mettemp
default|clear
Message ID = 165
Table 39: METTEMP Default Configuration
Field
Data
Value Used if
Not Specified
Bytes
Format
Units
Offset
1
Header
-
-
0
2
4
Enum
none
H
3
Temperature
0
4
Float
Celsius or
Fahrenhei
t
a
a. You may use Celsius or Fahrenheit in your float input, depending on your preference
H+4
Parameter
Power-On
Freset
Stored in NVM
metpress
clear
clear
NO