LASER FAULT INDICATIONS
PAGE
|
82
Table 4-13 PWM Sense/Control Board fault
1 See the Laser fault indications section for details.
Laser fault indications
OEM v30 lasers can indicate five specific fault conditions. In the event of certain faults, the RDY LED,
PWR LED, or both will blink an error code, pause 1/2 second, and then repeat the code. This sequence
continues until the fault is corrected and the laser is reset by cycling DC power to the laser.
Table below lists fault codes, the corresponding fault condition, and describes possible corrective ac-
tions.
Table 4-14 Laser fault codes
Resetting faults
Remote interlock condition
A remote interlock condition occurs when the Laser Enable input opens (the RDY indicator turns off). On
OEM lasers, remote interlock conditions are not latched. Re-establish the Laser Enable signal input (RDY
LED changes from off to yellow) and begin lasing immediately.