INTERFACE CONNECTIONS
PAGE
|
55
Sample input circuits
Figure below illustrates one method of applying the Laser Enable signal using a customer-supplied limit
switch or relay contact powered by the OEM v30’s DC Out output (+5 V, 250 mA).
Figure 3-6 OEM v30 powered Laser Enable circuit
Figure below shows another variation for applying a Laser Enable signal. In this case, the customer is
also supplying the voltage necessary to drive the v30’s enable circuit.
Figure 3-7 Customer powered Laser Enable circuit
Figure below shows an isolated PLC output module switching the Laser Enable signal from a +5 V
source.
Caution: Possible Equipment Damage
The Interface A (DB-9) Laser Enable input is a direct 5V logic input. Do not send a voltage signal to
the Laser Enable input (Pin 9) until DC power is applied; otherwise, the control board will be
damaged. Observe all 5V logic specifications and precautions when integrating OEM v30 inputs and
outputs into your control system.