INTERFACE CONNECTIONS
PAGE
|
63
Table 3-8 RJ45 output circuit specifications
Figure 3-15 RJ45 output equivalent schematic
Sample output circuit
You can monitor OEM v30 laser status remotely by connecting one or more outputs to an isolated 5 VDC solid state relay or PLC input
module. Figure below illustrates the connections required to monitor the RJ45’s Laser OK status, or any other RJ45 output, using an
isolated 5 VDC input module.
Output Signals
Output device type and specifications
Laser OK
5V logic output buffer
Temperature OK
On state Vmin +4.5 VDC @ 50
mA
Voltage OK
On state (typical) +5.0 VDC @
0.5 mA
Off state Vmax +0.8 VDC