WATER-COOLED CONNECTIONS
PAGE
|
31
Cooling tubing connections
The following procedure will guide you in configuring the most efficient cooling system. Please connect
your system exactly as described below.
To connect cooling tubing to your v30 laser, refer to Figure 1-3 and perform the following steps.
Figure 1-3 OEM v30 cooling connections
1.
Cut and connect a length of 1/2-inch O.D. polyethylene cooling tubing to fit between the chiller’s
Outlet port and the upper WATER IN port on the rear of the OEM v30 laser.
2.
Cut and connect a length of tubing to fit between the lower WATER OUT port on the rear of the
laser and the chiller’s Inlet port.
Caution: Possible Equipment Damage
Operating the laser at coolant temperatures above 22 °C (72 °F) may result in decreased
performance and/or premature failure of electronic components.
Caution: Possible Equipment Damage
Inlet cooling water temperature must always be maintained above the dew point to prevent
condensation and water damage to your laser.
Содержание v30
Страница 1: ...ENGINEERED BY SYNRAD v30 Laser User Manual...
Страница 16: ...OEM V30 LASER LABEL LOCATIONS PAGE 16 OEM v30 Laser label locations...
Страница 22: ...DECLARATION OF CONFORMITY PAGE 22 Declaration of conformity Figure 2 Declaration Document...
Страница 64: ...INTERFACE CONNECTIONS PAGE 64 Figure 3 16 Laser OK output to PLC input...
Страница 90: ...BEAM DELIVERY OPTICS PAGE 90 This page is left blank intentionally...
Страница 100: ...INDEX PAGE 1 This page is intentionally left blank...