INTERFACE CONNECTIONS
PAGE
|
57
Figure 3-9 DB-9 output equivalent schematic
Sample output circuit
You can monitor OEM v30 laser status remotely by connecting one or more outputs to an isolated 5 VDC solid state relay or PLC input
module. Figure below illustrates the connections required to monitor the DB-9’s Lase Indicator status, or any other DB-9 output, using an
isolated 5 VDC input module.
Figure 3-10 Lase Indicator output to PLC input