PRECESSION ELEPHANT 2 Scan Head 2
6.5 Checking the settings on the ASC system controller
In the normal case you get an ASC system controller with your scan head, where all
required device drivers are already installed.
If this is not the case then you have to create, configure and activate the necessary
devices first. This section lists these devices.
TIP
Learn how to manage devices in general from document [
], e.g. how to create,
configure, activate them.
Learn how to configure and use specific devices from document [
Even in the normal case it is advisable to check settings on the ASC system controller
with the secondary effect of learning how to manage devices and how to configure, to
parametrize and to use them in the InScript software.
•
Begin with section
on page
6.5.1 Head device
Procedure
1. In the InScript software in the
Navigator
view, in the controlle
r’s
Devices
subtree,
select the
head
device.
2. In the
Node Properties
view on the
Configuration
tab, check, if the following
variables are set to the values listed below and correct them if necessary.
Parameter
Value
Vector processing
VP1 Enabled
Scan field correction
COR1 Enabled
Output channel modifiers OCM1 Enabled
Axis configuration
X/Y/Z/A
Number of subfames
6
1. In the InScript software in the
Navigator
view in the controller’s
Pens
subtree,
select the
default
head
pen-section.
32