PRECESSION ELEPHANT 2 Scan Head 2
Nomenclature
1
2
3
4
No. Name
①
(Self-sealing) quick coupling
②
Release bushing
③
(Self-sealing) plug nipple
Figure 4: Parts of a cooling water connector
④
Coupling nut
How to install the plug nipple to the flexible tube
1. Slip the coupling nut
④
onto the flexible tube.
2. Push the flexible tube onto the plug nipple
③
.
3. Tighten the coupling nut
④
.
How to connect
1. Turn the cooling water flow off.
2. Relieve the pressure from the tubing.
3.
TIP
A small amount of cooling water may leak. Wipe it off with a tissue.
Quickly press the plug nipple
③
beyond the resistance into the quick
coupling
①
.
4. Check for leakage.
How to disconnect
1. Turn the cooling water flow off.
2. Relieve the pressure from the tubing.
3. Push the release bushing
②
in direction of the heat sink.
27