Troubleshooting
8-11
Part 1126187_05
E
2021
Nordson Corporation
Corrective Action(s)
Cause
Effect on
Controller
Screen Message
Internal
Communication Alert
The board returns
one of the following
fault codes:
S
CPU PCA
S
I/O and
Temperature
Control Board
Improperly connected or
defective board-to-board wiring
S
Check board-to-board wiring.
S
Replace the board.
S
Check diagnostic indicator
lights on each board.
Software Upgrade
Fail Fault
The upgrade is
unsuccessful.
S
Power interruption while the
upgrade is in progress
S
The file is not properly
downloaded or is corrupt.
S
Try upgrading again.
S
Download the upgrade file
again.
External
Communication Alert
The controller
cannot communicate
with robot or parent
machine (external
device).
S
Cable not connected or
connected properly.
S
Parent machine is Off.
S
Check that the cable
connections are seated
properly.
S
Make sure the parent
machine is not On.
Содержание Vulcan Jet
Страница 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 38: ...Installation 3 12 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 110: ...Advanced Controller Configuration 6 36 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 121: ...Maintenance 7 5 Part 1126187_05 E 2021 Nordson Corporation 1 2 3 5 4 4 6 7 8 Figure 7 2 General Disassembly...
Страница 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Страница 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Страница 166: ...Parts 9 8 Part 1126187_05 E 2021 Nordson Corporation 5 1 4 2 20 5 9 8 6 7 6X 19 3 Figure 9 5 Controller Assembly...
Страница 171: ......
Страница 172: ......