Disabling the Applicators
NOTE:
Adhesive dispensing applicators are referred to as “guns” in some
previous publications.
All electrical or mechanical devices that provide an activation signal to the
applicators, applicator solenoid valve(s), or the melter pump must be
disabled before work can be performed on or around an applicator that is
connected to a pressurized system.
1. Turn off or disconnect the applicator triggering device (robot, timer,
Programmable Logic Controller [PLC], etc.).
2. Disconnect the input signal wiring to the applicator.
3. Reduce the air pressure to the system, then relieve the residual air
pressure between the air control kit and the applicator.