Troubleshooting
8-12
Part 1126187_05
E
2021
Nordson Corporation
Temperature Alarm Troubleshooting
Refer to this table to troubleshoot temperature alarms generated by the
heater/RTD.
Table
8-6 Temperature Alerts/Faults
Screen Message
Effect on
Controller
Cause
Corrective Action(s)
Overtemperature
Alert condition
-
Temperature for
Zone <<# or
Name>> rises above
defined Set Point
threshold. The
controller continues
to work, but
maintenance may be
required.
Fault condition
-
Temperature for
Zone <<# or
Name>> rises above
defined Set Point
threshold. Heaters
turned Off.
The actual temperature of the
component has risen above the
set temperature limit.
S
Check the connections or
replace the RTD.
S
Check for conditions that
may cause an increase in
ambient temperature.
S
Replace the component.
S
Install P/N 1126121 Heat
Exchanger Air Flush Kit. See
page 3-7.
Undertemperature
Alert condition
-
Temperature for
Zone <<# or
Name>> drops
below defined Set
Point threshold. The
controller continues
to work, but
maintenance may be
required.
Fault condition
-
Temperature for
Zone <<# or
Name>> drops
below defined Set
Point threshold.
Heaters turned Off.
The actual temperature of the
component has dropped below
the set temperature limit.
S
Check the connections or
replace the RTD.
S
Check for conditions that
may cause a drop in ambient
temperature.
S
Replace the component.
Open/Shorted
RTD on shorted or
open on <<# or
Name>>. Controller
not working.
S
The RTD for the component
indicated has failed.
S
The component was
disconnected from the
controller.
Check the connections or
replace the RTD.
Содержание Vulcan Jet
Страница 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 38: ...Installation 3 12 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 110: ...Advanced Controller Configuration 6 36 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 121: ...Maintenance 7 5 Part 1126187_05 E 2021 Nordson Corporation 1 2 3 5 4 4 6 7 8 Figure 7 2 General Disassembly...
Страница 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Страница 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Страница 166: ...Parts 9 8 Part 1126187_05 E 2021 Nordson Corporation 5 1 4 2 20 5 9 8 6 7 6X 19 3 Figure 9 5 Controller Assembly...
Страница 171: ......
Страница 172: ......