Troubleshooting
8-8
Part 1126187_05
E
2021
Nordson Corporation
Storage Alarm Troubleshooting
Refer to this table to troubleshoot the alarms generated by the storage
components.
Table
Screen Message
Effect on
Controller
Cause
Corrective Action(s)
USB File Error - Disk
Full Alert
Error saving file. Not
enough space to
save the file
S
Use a different USB drive.
S
Delete some files from the
disk.
USB File Error -
Corrupt File Alert
Error reading file.
File is corrupt.
Reload file onto USB drive.
CRC File Error On
Panel Fault
Error verifying panel
software
Reinstall software using the
archive recovery screen.
If recovery fails, upgrade
software via USB
File Transfer Failed
Alert
File fails to transfer
during back-up or
restore operation.
Try backup or restore again.
Recipe File Error
Alert
CRC check fails
when recipe is
opened.
Delete the recipe and re-create it
Recipe Changes Not
Saved Alert
Changes made to
the recipe are not
saved due to power
loss or remote
recipe change.
Always save recipe changes that
you wish to save.
Содержание Vulcan Jet
Страница 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 38: ...Installation 3 12 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 110: ...Advanced Controller Configuration 6 36 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 121: ...Maintenance 7 5 Part 1126187_05 E 2021 Nordson Corporation 1 2 3 5 4 4 6 7 8 Figure 7 2 General Disassembly...
Страница 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Страница 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Страница 166: ...Parts 9 8 Part 1126187_05 E 2021 Nordson Corporation 5 1 4 2 20 5 9 8 6 7 6X 19 3 Figure 9 5 Controller Assembly...
Страница 171: ......
Страница 172: ......