Troubleshooting
8-3
Part 1126187_05
E
2021
Nordson Corporation
Table
8-1 Heater/RTD Alerts/Faults
Screen Message
Effect on
Controller
Cause
Corrective Action(s)
Nozzle Heater
Current Overload
Fault
Nozzle heater
current has
exceeded the
allowable limit.
Heater turned off.
S
Defective heater
S
Short circuit in heater wires
Inspect heater wiring. Otherwise,
replace heater assembly. If
condition still exits, replace I/O
PCA board.
Cartridge Heater
Current Overload
Fault
Cartridge heater
current has
exceeded the
allowable limit.
Heater turned off.
Nozzle Heater Open
Alert condition
-
nozzle heater
current has
exceeded the
allowable limit.
Fault condition
- if
the issue is not
resolved within 2
minutes of the alert
message, the heater
is switched off.
S
Defective heater
S
Open circuit in the heater
wiring
S
Defective I/O Printed Circuit
Assembly (PCA) board
Cartridge Heater
Open
Alert condition
-
cartridge heater
current has
exceeded the
allowable limit.
Fault condition
- if
the issue is not
resolved within 2
minutes of the alert
message, the heater
is switched off.
Содержание Vulcan Jet
Страница 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 38: ...Installation 3 12 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 110: ...Advanced Controller Configuration 6 36 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 121: ...Maintenance 7 5 Part 1126187_05 E 2021 Nordson Corporation 1 2 3 5 4 4 6 7 8 Figure 7 2 General Disassembly...
Страница 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Страница 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Страница 166: ...Parts 9 8 Part 1126187_05 E 2021 Nordson Corporation 5 1 4 2 20 5 9 8 6 7 6X 19 3 Figure 9 5 Controller Assembly...
Страница 171: ......
Страница 172: ......