Advanced Controller Configuration
6-32
Part 1126187_05
E
2021
Nordson Corporation
Default User Settings and Ranges
The following table details default settings and ranges for user-definable
melter, temperature, pump, and melter settings.
Temperature Settings
Setting
Default
Range/Option
Heated Zone Set Points / Global
Set Point
115
_
C (240
_
F)
Minimum: 37.8
_
C (100
_
F)
Maximum: 190
_
C (374
_
F)
Temperature Limits
Over Temp: 15
_
C (25
_
F)
Minimum: 5
_
C (10
_
F)
Maximum: 60
_
C (110
_
F)
Under Temp: 25
_
C (50
_
F)
Minimum: 9
_
C (16
_
F)
Maximum: 60
_
C (110
_
F)
Auto Standby Start Time
60 minutes
Minimum: 1 minute
Maximum: 180 minutes
Auto Heaters Off Time
60 minutes
Minimum: 0 minutes
Maximum: 1440 minutes
Auto Exit Standby Time
Disabled
Enabled
Disabled
Auto Exit Standby Time
45 minutes
Minimum: 1 minute
Maximum: 180 minutes
Standby Temp
50
_
C (100
_
F)
Minimum: 5
_
C (10
_
F)
Maximum: 60
_
C (110
_
F)
Содержание Vulcan Jet
Страница 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 38: ...Installation 3 12 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 110: ...Advanced Controller Configuration 6 36 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Страница 121: ...Maintenance 7 5 Part 1126187_05 E 2021 Nordson Corporation 1 2 3 5 4 4 6 7 8 Figure 7 2 General Disassembly...
Страница 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Страница 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Страница 166: ...Parts 9 8 Part 1126187_05 E 2021 Nordson Corporation 5 1 4 2 20 5 9 8 6 7 6X 19 3 Figure 9 5 Controller Assembly...
Страница 171: ......
Страница 172: ......