71
I. It appears there is
no power to the
machine.
Check For:
A. Main Power
Verify that the main switch located at the front of the oven is in the
“ON” (
Ө
)
position.
1. Check the incoming supply lines to the oven and verify they
are supplying the required voltage as marked on the serial tag.
Using a multi-meter set to measure AC volts, probe the main
switch terminals L1, L2 and L3. Each combination (L1-L2, L2-
L3 and L1-L3) should be verified. If the correct voltage is not
found on one or more phases, there is a problem with the
power supply in the facility.