80
III. Computer reports
low deviation of a
heat zone or a zone
not reaching
temperature.
Check For:
A. Software
1. Choose Channel Setup from the Window menu. Select the
Heat zone channel in question using arrow key. (A typical
channel setup screen for a heat zone is shown in
figure 5
)
Figure
5
2. Verify that the alarm deviation is set to at least 40 degrees C.
(The deviation is factory set to 40
o
C)
3. Verify that the control output is set in “AUTO” mode. (The
software should automatically set the power output to 100%)
4. Verify that the TI value should be set to 500 for IR panel
heaters.