94
C. Conveyor Motor
1. Look at the shaft of the conveyor drive motor located behind
the conveyor cover on the front, exit end of the machine. If it is
turning, proceed to step D.
2. With the power leads removed from motor, check the DC
voltage between the motor supply leads. If it is zero volts,
proceed to step E.
3. With the power leads removed from the motor, check for
continuity between the motor leads and earth ground using the
multimeter set to the ohm scale. Continuity indicated that the
motor should be replaced. Also check the resistance of the
motor windings. If there is a short or open circuit, replace the
motor.
4. Check carbon brushes after every 2000 hours of operation. If
the length of either brush is 3/16” (4.8mm) or less, replace
both brushes with the same grade of material. See
maintenance section for inspection/replace procedure.