96
It should be +5.00 V DC at 100% output. If AC voltage OR signal
voltage is zero (0 V) then check the wiring for motor speed
controller. (See main electrical wiring schematics)
X. EHC/MESH BELT DC Motor Controller Adjustments
NOTE
:
The PCB transport system controller has been set at the factory. Adjustment to the motor speed
controllers described here is not recommended without first consulting the Asymtek Service Department.
This section specifies the procedure for the calibration of the oven EHC/Mesh belt transport system motor
controller located on the electrical panel. (CP # 4491)
The calibration procedure should be performed after the oven has been powered and computer control of the
EHC/mesh belt transport system has been established.
The calibration should be performed in the following order:
1. MIN speed trimpot adjustments.
2. MAX speed trimpot adjustments.
3. Current Limit adjustment.
Before starting any adjustment, verify the “ACCEL” trimpot on the controller is set at the 1 o’clock position, verify
the “IR” trimpot is set at the 10 o’clock position, and verify the “CL” trimpot is set at the 12 o’clock position (
See
Figure 15
).
Содержание TCM-2200
Страница 5: ...1 Introduction ...
Страница 6: ...2 ...
Страница 18: ...14 ...
Страница 19: ...15 Facility Installation ...
Страница 20: ...16 ...
Страница 26: ...22 ...
Страница 27: ...23 Operating System Software Guide ...
Страница 28: ...24 ...
Страница 55: ...51 ...
Страница 56: ...52 ...
Страница 57: ...53 ...
Страница 58: ...54 ...
Страница 64: ...60 ...
Страница 65: ...61 Standard and Optional Equipment Operating Guide ...
Страница 66: ...62 ...
Страница 71: ...67 Troubleshooting Guide HC1 X or HC2 controller ...
Страница 72: ...68 ...
Страница 74: ...70 ...
Страница 95: ...91 Figure 12 ...
Страница 107: ...103 Maintenance Procedure ...
Страница 108: ...104 ...
Страница 110: ...106 ...