3. The Alarm and Warning section contain edit boxes that allow the user to insert a deviation
number around the set point and process values as redundant alarm set-points.
4. The current channel data section displays the current actual measured variable in temperature,
speed or position process variable (PV) and the percentage of full-scale output being applied
output percentage (OP). There is an edit box for the channel set point (SP).
5. The graph section plots the actual readings of the current channel. The history data of the graph
is recoverable from the daily journal database file.
6. The alarm and warning enable section contain check boxes to enable or disable deviation and
process alarms and warnings. Also list boxes to display actual messages associated with the
values.
7. The control section contains a list box for the type of control for the channel (Auto, Manual or
Off), an edit box to enter a percentage of output for manual control, and an edit box to enter an
alarm dead-band.
Again it is not recommended that the channel parameters other than the Set point be
changed without first consulting with the factory service department. Making these
changes may cause abnormal machine operation and may lead to a hazardous condition.
M. Modifying a Recipe / Creating a new Recipe
Recipes can be modified in operate or edit mode. While in operate mode, the oven will respond
to set point changes and if the user is satisfied with the results can click the Save icon on the
main toolbar or from the menu bar click Recipe then Save.
New recipes can be created in operate or edit mode. Change the set points as required for the
new recipe, click on Recipe -> Save As, type new name and save the recipe. In operate mode
channels will respond to set point changes.
N. Loading a Recipe
In the operate mode Recipe Open will allow the user to load a new recipe to the oven. The user
will be prompted that you are in the operate mode are you sure you want to load a different
recipe. Clicking yes will display the recipe listing for the user to load.
O. Deleting a recipe
To delete a recipe, open Windows Explorer. Under the ‘C:’ drive, open the folder labeled ‘oven’,
and then open the folder labeled ‘Recipe Files’. This folder contains the recipes for the machine
(file names with extension ‘job’). The system default recipe (1088.job, 1705.job, 1706.job,
1707.job, 1808.job, 1809.job, 1912.job, 1913.job corresponding to the model number) should not
be deleted, if deleted it will be created automatically after application is restarted. A recipe in
operation cannot be deleted.
P. Software Version
The version of software currently running the system can be found by clicking from the menu bar
Help then About. This information may be necessary when calling the factory service department
for assistance.
Figure 47
Содержание TCM-2200
Страница 5: ...1 Introduction ...
Страница 6: ...2 ...
Страница 18: ...14 ...
Страница 19: ...15 Facility Installation ...
Страница 20: ...16 ...
Страница 26: ...22 ...
Страница 27: ...23 Operating System Software Guide ...
Страница 28: ...24 ...
Страница 55: ...51 ...
Страница 56: ...52 ...
Страница 57: ...53 ...
Страница 58: ...54 ...
Страница 64: ...60 ...
Страница 65: ...61 Standard and Optional Equipment Operating Guide ...
Страница 66: ...62 ...
Страница 71: ...67 Troubleshooting Guide HC1 X or HC2 controller ...
Страница 72: ...68 ...
Страница 74: ...70 ...
Страница 95: ...91 Figure 12 ...
Страница 107: ...103 Maintenance Procedure ...
Страница 108: ...104 ...
Страница 110: ...106 ...