5 Parameter
BU 0180 en-4118
153
P716
Current frequency
(Actual frequency)
-400.0 ... 400.0 Hz
Displays the actual output frequency.
P717
Current speed
(Actual rotation speed)
-9999 ... 9999 rpm
Displays the actual motor speed calculated by the FI.
P718
[-01]
...
[-03]
Present Actual setpoint
frequency
(Actual setpoint frequency)
-400.0 ... 400.0 Hz
Displays the frequency specified by the setpoint
(please see chapter 8.1 "Setpoint processing").
[-01] =
Actual setpoint frequency from the setpoint source
[-02] =
Actual setpoint frequency after processing in the FI status machine
[-03] =
Actual setpoint frequency after frequency ramp
P719
Actual current
(Actual current)
0.0 ... 999.9 A
Displays the actual output current.
P720
Act. torque current
(Actual torque current)
-999.9 ... 999.9 A
Displays the actual calculated torque-developing output current (active current). Basis for
calculation are the motor data P201...P209.
negative values = generator,
positive values = drive
P721
Actual field current
(Actual field current)
-999.9 ... 999.9 A
Displays the actual calculated field current (reactive current). Basis for calculation are the motor
data P201...P209.
P722
Current voltage
(Actual voltage)
0 ... 500 V
Displays the actual AC voltage supplied by the FI output.
P723
Voltage -d
(Actual voltage component U
d)
S
-500 ... 500 V
Displays the actual field voltage component.
P724
Voltage -q
(Actual voltage component Uq)
S
-500 ... 500 V
Displays the actual torque voltage component.
Содержание SK 180E Series
Страница 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Страница 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Страница 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Страница 211: ...Key word index BU 0180 en 4118 211...
Страница 212: ...6071802 4118...