NORDAC BASE (SK 180E / SK 190E) – Users Manual for Frequency Inverters
150
BU 0180 en-4118
P701
[-01]
...
[-05]
Last fault 1 ... 5
(Last fault 1...5)
0.0 ... 25.4
This parameter stores the last 5 faults
(please see section "Error messages").
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
P702
[-01]
...
[-05]
Last frequency error
(Last frequency error 1...5)
S
-400.0 ... 400.0 Hz
This parameter stores the output frequency that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK- / ENTER key to read the stored error code.
P703
[-01]
...
[-05]
Current last error
(Last current error 1...5)
S
0.0 ... 999.9 A
This parameter stores the output current that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
P704
[-01]
...
[-05]
Volt. last error
(Last voltage error 1...5)
S
0 ... 600 V AC
This parameter stores the output voltage that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
P705
[-01]
...
[-05]
Last link circuit error
(
Last link circuit error 1...5)
S
0 ... 1000 V DC
This parameter stores the link voltage that was being delivered at the time the error occurred. The
values of the last 5 errors are stored.
The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.
Содержание SK 180E Series
Страница 1: ...BU 0180 en NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters...
Страница 4: ...NORDAC BASE SK 180E SK 190E Users Manual for Frequency Inverters 4 BU 0180 en 4118...
Страница 185: ...8 Additional information BU 0180 en 4118 185 8 3 4 EU Declaration of Conformity...
Страница 211: ...Key word index BU 0180 en 4118 211...
Страница 212: ...6071802 4118...